Gold Member Since 2006
Audited Supplier
CNC Electric Group Co., Ltd.

Lr9 Thermal Relay, Lr9 Relay, Oem Relay manufacturer / supplier in China, offering Electronic Relay/ (JR28) Thermal Overload Relay /Thermal Relay, Hot Product Residual Current Circuit Breaker (YCB7LE-1P+N), Distribution Box (YC-XSA) and so on.

(/ )

Supplier Homepage Product Industrial Control Relay Electronic Relay/ (JR28) Thermal Overload Relay /Thermal Relay

Electronic Relay/ (JR28) Thermal Overload Relay /Thermal Relay

FOB Price: Get Latest Price
Min. Order: 50 Pieces
Production Capacity: 10, 000 PCS/Day
Transport Package: Standard Export Packing
Payment Terms: L/C, T/T, D/P, Paypal, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: JR28
  • Usage: Lathe Relay
  • Electricity Type: Ac
  • Load: High Power Relay
  • Size: Miniature
  • Rated Voltage: 80~800V
  • Trademark: CNC
  • Origin: China
  • Theory: Electromagnetic Relay
  • Phase: 3
  • Number of Pole: 3
  • Protective Characteristics: Sealed Relay
  • Type: Electric Parameter Relay
  • Rated Insulating Voltage: 690V
  • Specification: IEC 60947-3
  • HS Code: 85352100
Product Description
electronic Relay/(JR28)thermal overload relay /Thermal relay 
1. Standard: IEC60947-4-1
2. Rated voltage: 80~800V
3. Rated insulating voltage: 690V

electronic Relay/(JR28)thermal overload relay /Thermal relay  

  Working principle

     electronic Relay/(JR28)thermal overload relay /Thermal relay  is generated by the current into components of heat, make have different expansion coefficient of bimetallic strip deformation occurs, when the deformation reaches a certain distance, just push rod action, make the control circuit disconnect, so that the contactor, losing electricity main circuit disconnect, realizes the motor overload protection.

  Main role 

          Mainly used for asynchronous motor overload protection, It works for overload electrical current overheated components, bimetallic strip heating bend to promote action mechanism to drive the contact action, to disconnect the motor control circuit is to secure a motor power, have the effect of overload protection. In view of the bimetallic strip heated bending process, the heat transfer need a long time, therefore, thermal relay cannot be used as a short circuit protection, and can only be used for overload protection of thermal relay overload protection.

 Parameter  
Electronic Relay/ (JR28) Thermal Overload Relay /Thermal Relay
Electronic Relay/ (JR28) Thermal Overload Relay /Thermal Relay

 Installation     

1. When placed, if the heating element in the lower part of bimetallic strip, bimetallic strip is soon hot, short action time;

2. If the heating element is next to the bimetallic strip, bimetallic strip hot are slower, the action of thermal relay long time;

3. When the thermal relay and other electrical appliances when put together, should be in below and away from other electrical appliances more than 50 mm, in order to avoid being influenced by other electric heating;

 Daily maintenance    

1, thermal relay action should be reset after a certain time, automatic reset time should be done in 5 minutes, manual reset after 2 minutes to press the reset button.

2, when the short-circuit fault, to check whether hot components and bimetallic strip deformation, if any abnormal situation, should be timely adjusted, but not element will be removed, nor bend a bimetallic strip.

3, the use of thermal relay should check once a week, the specific content is: thermal relay overheating, odor and discharge, all the parts with or without screw loose fall off and remove bad, surface without damage and clean or not.

4, the use of thermal relay should be maintenance once a year, the specific content is: cleaning, repair parts, testing insulation resistance should be greater than 1 megohm, electricity. After check thermal relay, in addition to the connection screw, screw other don't move.

5, change the thermal relay, the newly installed thermal relay must be in conformity with the original specifications and requirements.                                 

   Our service            

 

   In most time, the buyer need not to pay any customs. Well declare it as a gift and a low value to avoid the tax.But sometimes in some countries, the customs officer is strict.   We are not accountable for any customs fee, Please check it out the customs policy at your own place, such as Italy and Holland. If you have to pay thecustoms fees, it is your duty to your own country, the buyer should understand this situation. Buyers are responsible for any insurance. Please contact with us advance if you need.

 

   

Type Rated  working  curren Thermal  component
Rated  current  (A) Regular  or  scale  of  rated  current  (A)
JR28-36      36 0.16 0.10-0.16
0.25 0.16-0.25
0.4 0.25-0.40
0.63 0.40-0.63
1 0.63-1.0
1.6 1.0-1.6
2.5 1.6-2.5
4 2.5-4.0
6 4.0-6.0
8 5.5-8.0
10 7.0-10.0
13 9.0-13.0
18 12.0-18.0
25 17.0-25.0
JR28-93        93 32 23.0-32.0
40 30.00-40.00
50 38.00-50.00
57 48.00-57.00
66 57.00-66.00
80 28.0-36.0
 