Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer, General-Purpose High-Performance Current Vector |
Output Type: | Three Phase |
Still deciding? Get samples of US$ 80/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
YCB2000PV | T | 5D5 | G | |
Model | Output voltage | Adaptive power | Load type | |
Photovoltaic Inverter |
S: Single phase AC220V T: Three phase AC380V |
0D75:0.75KW 1D5:1.5KW 2D2:2.2KW 4D0:4.0KW 5D5:5.5KW 7D5:7.5KW 011:11KW 015:15KW .... 110:110KW |
G: Constant torque | |
Model | YCB2000PV-S0D7G | YCB2000PV-S1D5G | YCB2000PV-S2D2G | YCB2000PV-T2D2G | YCB2000PV-T4D0G | ||
Input data | |||||||
PV Source | |||||||
Max input voltage(Voc)[V] | 400 | 750 | |||||
Min input voltage, at mpp[V] | 180 | 350 | |||||
Recommended voltage,at mpp | 280VDC~360VDC | 500VDC~600VDC | |||||
Recommended amps input,at mpp[A] | 4.7 | 7.3 | 10.4 | 6.2 11.3 | |||
Recommended max power at mpp[kW] | 1.5 | 3 | 4.4 | 11 15 | |||
Alternate AC generator | |||||||
Input voltage | 220/230/240VAV(±15%),Single Phase | 380VAV(±15%) Three Phase | |||||
Max amps(RMS)[A] | 8.2 | 14.0 | 23 | 5.8 | 10.0 | ||
Power and va capability [kVA] | 2.0 | 3.1 | 5.1 | 5.0 | 6.6 | ||
Output data | |||||||
Rated output power[kW] | 0.75 | 1.5 | 2.2 | 2.2 | 4 | ||
Rated output voltage | 220/230/240VAC,Single Phase | 380VAC,Three Phase | |||||
Max amps(RMS)[A] | 4.5 | 7.0 | 10 | 5.0 | 9.0 | ||
Output frequency | 0-50Hz/60Hz | ||||||
Pump system configuration parameters | |||||||
Recommended solar panel power(KW) | 1.0-1.2 | 2.0-2.4 | 3.0-3.5 | 3.0-3.5 | 5.2-6.4 | ||
Solar panel connection | 250W×5P×30V | 250W×10P×30V | 250W×14P×30V | 250W×20P×30V | 250W×22P×30V | ||
Applicable pump (kW) | 0.37-0.55 | 0.75-1.1 | 1.5 | 1.5 | 2.2-3 | ||
Pump motor voltage(V) | 3 phase 220 | 3 phase 220 | 3 phase 220 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T5D5G | YCB2000PV-T7D5G | YCB2000PV-T011G | YCB2000PV-T015G | YCB2000PV-T018G | |||
Input data | ||||||||
PV source | ||||||||
Max input voltage(Voc)[V] | 750 | |||||||
Min input voltage, at mpp[V] | 350 | |||||||
Recommended voltage,at mpp | 500VDC~600VDC | |||||||
Recommended amps input,at mpp[A] | 16.2 | 21.2 | 31.2 | 39.6 | 46.8 | |||
Recommended max power at mpp[kW] | 22 | 30 | 22 | 30 | 37 | |||
Alternate AC generator | ||||||||
Input voltage | 380VAV(±15%) ,Three Phase | |||||||
Max amps(RMS)[A] | 15 | 20 | 26.0 | 35.0 | 46.0 | |||
Power and va capability [kVA] | 9.0 | 13.0 | 17.0 | 23.0 | 25 | |||
Output data | ||||||||
Rated output power[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 | |||
Rated output voltage | 380VAC,Three Phase | |||||||
Max amps(RMS)[A] | 13 | 17 | 25.0 | 32.0 | 37 | |||
Output frequency | 0-50Hz/60Hz | |||||||
Pump system configuration parameters | ||||||||
Recommended solar panel power(KW) | 7.2-8.8 | 9.8-12 | 14.3-17.6 | 19.5-24 | 24-29.6 | |||
Solar panel connection | 250W×40P×30V 20 series 2 parallel |
250W×48P×30V 24 series 2 parallel |
250W×60P×30V 20 series 3 parallel |
250W×84P×30V 21 series 4 parallel |
250W×100P×30V 20 series 5 parallel |
|||
Applicable pump (kW) | 3.7-4 | 4.5-5.5 | 7.5-9.2 | 11-13 | 15 | |||
Pump motor voltage(V) | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T022G | YCB2000PV-T030G | YCB2000PV-T037G | YCB2000PV-T045G | |||||
Input data | |||||||||
PV source | |||||||||
Max input voltage(Voc)[V] | 750 | ||||||||
Min input voltage, at mpp[V] | 350 | ||||||||
Recommended voltage,at mpp | 500VDC~600VDC | ||||||||
Recommended amps input,at mpp[A] | 56.0 | 74.0 | 94.0 | 113 | |||||
Recommended max power at mpp[kW] | 44 | 60 | 74 | 90 | |||||
Alternate AC generator | |||||||||
Input voltage | 380VAV(±15%) ,Three Phase | ||||||||
Max amps(RMS)[A] | 62.0 | 76.0 | 76.0 | 90.0 | |||||
Power and va capability [kVA] | 30.0 | 41.0 | 50.0 | 59.2 | |||||
Output data | |||||||||
Rated output power[kW] | 22 | 30 | 37 | 45 | |||||
Rated output voltage | 380VAC,Three Phase | ||||||||
Max amps(RMS)[A] | 45 | 60 | 75 | 90 | |||||
Output frequency | 0-50Hz/60Hz | ||||||||
Pump system configuration parameters | |||||||||
Recommended solar panel power(KW) | 28.6-35.2 | 39-48 | 48.1-59.2 | 58.5-72 | |||||
Solar panel connection | 250W×120P×30V 20 series 6 parallel |
250W×200P×30V 20 series 10 parallel |
250W×240P×30V 22 series 12 parallel |
250W×84P×30V 21 series 4 parallel |
|||||
Applicable pump (kW) | 18.5 | 22-26 | 30 | 37-40 | |||||
Pump motor voltage(V) | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T055G | YCB2000PV-T075G | YCB2000PV-T090G | YCB2000PV-T110G | ||||
Input data | ||||||||
PV source | ||||||||
Max input voltage(Voc)[V] | 750 | |||||||
Min input voltage, at mpp[V] | 350 | |||||||
Recommended voltage,at mpp | 500VDC~600VDC | |||||||
Recommended amps input,at mpp[A] | 105 | 140 | 160 | 210 | ||||
Recommended max power at mpp[kW] | 55 | 75 | 90 | 110 | ||||
Alternate AC generator | ||||||||
Input voltage | 380VAV(±15%) ,Three Phase | |||||||
Max amps(RMS)[A] | 113 | 157 | 180 | 214 | ||||
Power and va capability [kVA] | 85 | 114 | 134 | |||||
160 | ||||||||
Output data | ||||||||
Rated output power[kW] | 55 | 75 | 93 | 110 | ||||
Rated output voltage | 380VAC,Three Phase | |||||||
Max amps(RMS)[A] | 112 | 150 | 176 | 210 | ||||
Output frequency | 0-50Hz/60Hz | |||||||
Pump system configuration parameters | ||||||||
Recommended solar panel power(KW) | 53-57 | 73-80 | 87-95 | 98-115 | ||||
Solar panel connection | 400W*147P*30V 21series 7 parallel |
400W*200P*30V 20 series 10 parallel |
400W*240P*30V 20 series 12 parallel |
400W*280P*30V 20 series 4 parallel |
||||
Applicable pump (kW) | 55 | 75 | 90 | 110 | ||||
Pump motor voltage(V) | 3PH 380V | |||||||
Model | Size | W(mm) | H(mm) | D(mm) | A(mm) | B(mm) | Mounting Aperture |
||||||||||||||||
YCB2000PV-S0D7G | 125 | 185 | 163 | 115 | 175 | 4 | |||||||||||||||||
YCB2000PV-S1D5G | |||||||||||||||||||||||
YCB2000PV-S2D2G | |||||||||||||||||||||||
YCB2000PV-T0D7G | |||||||||||||||||||||||
YCB2000PV-T1D5G | |||||||||||||||||||||||
YCB2000PV-T2D2G | |||||||||||||||||||||||
YCB2000PV-T3D0G | 150 | 246 | 179 | 136 | 230 | 4 | |||||||||||||||||
YCB2000PV-T4D0G | |||||||||||||||||||||||
YCB2000PV-T5D5G | |||||||||||||||||||||||
YCB2000PV-T7D5G | |||||||||||||||||||||||
YCB2000PV-T011G | 218 | 320 | 218 | 201 | 306 | 5 | |||||||||||||||||
YCB2000PV-T015G | |||||||||||||||||||||||
YCB2000PV-T018G | |||||||||||||||||||||||
YCB2000PV-T022G | 235 | 420 | 210 | 150 | 404 | 5 | |||||||||||||||||
YCB2000PV-T030G | 270 | 460 | 220 | 195 | 433 | 6 | |||||||||||||||||
YCB2000PV-T037G | |||||||||||||||||||||||
YCB2000PV-T045G | 320 | 565 | 275 | 240 | 537 | 6 | |||||||||||||||||
YCB2000PV-T055G | |||||||||||||||||||||||
YCB2000PV-T075G | 380 | 670 | 272 | 274 | 640 | 8 | |||||||||||||||||
YCB2000PV-T090G | |||||||||||||||||||||||
YCB2000PV-T110G |