Customization: | Available |
---|---|
Competitive Quotation: | Yes |
Transport Package: | CNC Brand /Neutral Packing |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Item Description | |
Output |
Rated voltage, frequency | Sing |
Permissible working voltage |
Effective value of voltage: 220V class 180~230V, 380V class 320~460V Voltage unbalanced rate: <3%; Frequency error: ≤+5% | |
Input |
Rated voltage | Three phases 0~input voltage |
Frequency | 0~400Hz | |
Overloading capacity |
G type: 110% long term, 150% 1min, 180% 1s, 200% instantaneous trip P type: 120% 1min, 150% 1s, 180% instantaneous trip |
|
Control Function |
Working mode | Electromagnetic vector PWM modulation |
Adjustment range | 1:100 | |
Starting torque | 100% rated torque at 3Hz | |
Frequency accuracy |
Digital setting: highest frequency×±0.01% Analog setting: highest frequency×±0.2% | |
Freq dissolutions | Digital setting: 0.01Hz; Analog setting: highest frequency×0.1% | |
Torque |
Automatically rise torque up, according to output current it auto rise the torque up. Manually rise torque up, scope:1~30% | |
V/F curve |
|
|
Acceleration, slow-down time | 0.1~6000s continuous adjustment. | |
Compensation for rotation err |
orSetting scope: 0~20%, it can auto adjust the output frequency of inverter according to the motor loading, to reduce the speed change due the motor load fluctuates. | |
Built-in PID |
Easily form the loop control system, that it is suitable for pressure control, flux control and etc. | |
Auto voltage regulation |
When network voltage change, it can auto adjust the output of PWM and keep output voltage constant | |
Auto energy-saving run | As load change, it auto optimize the V/F curve, to realize the energy-saved running. | |
Running Function |
Freq setting |
The setting of Potentiometer in the panel: operation panel / key setting, terminal of outer control Rise / Drop setting, ananlog voltage signal or outer potentiometer setting, analog current signal setting, ananlog combination setting, setting of 485 serial communication. |
Running command | Control of operation panel, control of outer terminals, control of serial communication | |
Analog output terminal | 0~10V DC voltage signal output, can realize the output of frequency, current and etc, physical parameters | |
Input signal | Positive/megative rotation signal, multi-step signal, fault signal, resetting signal | |
Output signal | Programmable integrated circuit opening output, fault signal output |
Item | Item Description | |
Braking Function |
Braking by power consumpti | onOuter connected to braking resistance, maxi braking torque 100% |
Brake by direct current |
When starting or stopping, it is optional respectively, action frequency: 0-20Hz, action voltage level: 0-20%, action time 0-30s, continuously adjustable. | |
Other Function |
IJumpinf frequency, point function, counter, rotation speed track, restart after instan-staneous power off, upper and lower frequency limit, acceleration and slow-down modes adjustable, cymometer and voltmeter output, multi-step / program running, two lines / three lines control, double polar control, selection of multifunctional input terminal, auto reset after fault, 485 serial communication. | |
Protection Function |
Input protection against phase failure, over-current protection, overloading protection, under-voltage protection, overheating protection, output short circuit protection and etc. | |
LED Display |
It can display inverter real-time working status, monitoring parameters, function data, fault codes and etc. | |
Optional Accessories | Braking parts, remote and operation panel and connection wire, communication panel | |
Ambient Conditions |
Working site | Indoor, without direct sunshine, no dust, corrosive gas, flammable and explosive gas, oil fog, steam, water drop, salty |
Altitude | Altitude less than 1000m | |
Ambient temperature | -10-+45ºC (The only machine: -10~+50ºC) | |
Humidity | 20~90%RH, Without water condensation | |
Vibration | <0.5G | |
Storage temperature | -20~+60ºC | |
Protection grade | IP20 | |
Structure |
Cooling mode | Fan cooling |
Mounting mode | Wall hung type, standing type. |
YCB1000/380V | Appearance Size (mm) L×W×D |
Aperture Size of Panel (mm) L×H |
|||
No. | Model | Power | Voltage | ||
1 | YCB1000 |
0.75kW | 380V |
169×125×172 |
Panel: 75×55 Panel Cover: 95×61 |
2 | 1.5kW | ||||
3 | 2.2kW | ||||
4 | 4kW | 221×151×186 | |||
5 | 5.5kW | 280×190×182 | Panel: 130×70 Panel Cover: 156×80 |
||
6 | 7.5kW | ||||
7 | 11kW | 339×230×212 | |||
8 | 15kW | ||||
9 | 18.5kW | 450×280×260 | |||
10 | 22kW | ||||
11 | 30kW | 520×290×290 | |||
12 | 37kW | 580×290×320 |
|||
13 | 45kW | ||||
14 | 55kW | ||||
15 | 75kW | 630×380×350 | |||
16 | 90kW | ||||
17 | 110kW | 880×510×400 |
|||
18 | 132kW | ||||
19 | 160kW | ||||
20 | 185kW | 980×510×400 | |||
21 | 200kW | ||||
22 | 220kW | 1050×710×420 |
|||
23 | 250kW | ||||
24 | 280kW | ||||
25 | 315kW | ||||
26 | 350kW | 1900×800×420 |
|||
27 | 400kW | ||||
28 | 500kW |
YCB1000/220V | Appearance Size (mm) L×W×D |
||||
No. | Model | Power | Voltage | ||
1 | YCB1000 |
0.75kW | 220V |
142×85×122 |
|
2 | 1.5kW | ||||
3 | 2.2kW | 185×96×150 |