Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices

Product Details
Customization: Available
Type: Circuit Breaker
Structure: Moulded Case Circuit Breaker
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
  • Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
  • Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
  • Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
  • Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
  • Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
Find Similar Products

Basic Info.

Model NO.
YCD
Application
AC/DC System
Size
Meidum
Operation Voltage
Low Voltage
Shape
Cuboid
Material
Reinforce Flame Resistance PA66
Certification
ISO9001-2000
Brand
CNC
Breaking Capacity
Low Voltage Circuit Breakers
Max Persistent Voltage
385/420V
Rated Voltage
220/380V
Install DIN Rail
35mm DIN Rail
Max Connecting Wire Diameter
35mm2 Hard Wire
Working Temperature
-40~+80 ′c
Poles
1,2,3,4
Operation
Electric Type
Function
Surge Protector
Arc-Extinguishing Medium
Air
Transport Package
Standard Export Packing
Specification
IEC 60898
Trademark
CNC, OEM
Origin
Zhejiang, China
HS Code
85352100
Production Capacity
20, 000PCS/DAY

Product Description

 National Project Supplier Surge Arrester Ycd SPD Class C Surge Protection Devices
Specifications
YCD SPD class c surge protection devices
1. HS Code: 85362000
2. Standard: IEC 60898
3. Number of pole: 1, 2, 3, 4 Pole
4. Rated voltage: 75, 110, 220, 380 V
5. Rated current: Maximum 40 KA
6. Productivity: 20, 000PCS/DAY
7. Min. Order: 5, 000PCS
Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices
Ycs6 Series Surge Arrester AC/DC SPD 1p 2p 3p 4p 20-100ka Lightning Protection Class C Surge Protection Devices


YCD SPD class c surge protection devices
1. Type: YCD-B; YCD-C; YCD-D
2. General: When the power system suffered thunder of other reasons, it produces high frequency pulse voltage. The electrical equipment will be damaged. Especially with the large use of computer and microelectronic facilities, people have concerned the over protective device of low voltage power system. YCD surge protective device is the best product in terms of protection.
Appearance and mounting dimension: Protective device adopts 35mm Din rail type mounting appearance dimension see attachment.
Warning and counter function: Warning and counter(alarm) consists of optics alarm and thunder counter, the function as following:
AC 220v power supply for alarm, as the protector normal works that the pilot lamp is green, No contact is closed, NC contact is opened.
Acoustic optic alarm function: After the failure of protector mould, the buzzer, at the same time the green light change into red light. If you push the stop alarm button, the buzzer will pause (but red light continued), after 24 hours, if the trouble is not cleared, the buzzer sounds again.
Telecontrol function: The alarm is buzzing and it also can drop out close and cut off contact, for remote monitor.
Counter function: The alarm can display the protector's worktime, after push the stop button the numerals pipe appears the data of work time.
Self-inspection, zero function: Push stop button making current it can self-inspection and finish the numerals pope operating.
About CNC


1. China Top 500 Enterprise

2.26 years rich experience in manufacturing electrical products

3. Sales in over 100 countries

WHY US?

1. We Are Suppler of Three Gorges Project, China National Petroleum, Sinopec Group;

2. China Famous Export Enterprise, Our Products Sale in Over 100 Countries;

3. Our Laboratory is China Key Industrial Electrical Laboratory;

4. We have completely sales service system, ensure every detail is going smooth.

5. We have new designed products each year by our R&D Dpartment.

6. Perfect testing system ensure each product is qualified.

7. Want know more of us? Waiting for your inquiry.
Type   YCD-B YCD-C YCD-D
Protection class   B C D
Rated voltage Un V 220/380 380 220/380 220/380
Max persistant voltage Uc V 385/420 385 420-550 385/420 385 385/420 385
Protection level UP kv ≤ 1.5≤ 1.8 ≤ 2.0 ≤ 2.0-3.0 ≤ 1.5≤ 1.8 ≤ 2.0 ≤ 1.5≤ 1.8 ≤ 2.0 ≤ 2.0
Standard discharge current (8/20μ S) In ka 30 20 10
Max discharge current (8/20μ S) Imax ka 70 40 25
Response time ms < 25 < 25 < 25
Working temperature ° C -40~+80 -40~+80 -40~+80
Enclosure material Reinforce flame resistance PA66 Reinforce flame resistance PA66 Reinforce flame resistance PA66
Max connecting wire diameter mm 2 35mm 2 hard wire, 35mm 2 multi wire 35mm 2 hard wire, 35mm 2 multi wire 35mm 2 hard wire, 35mm 2 multi wire
Max connecting wire diameter of long distance monitor terminal mm 2 1.5mm 2 hard wire 1.5mm 2 hard wire 1.5mm 2 hard wire
Max fuse current A 63-100 32 16
Install DIN rail 35mm DIN rail 35mm DIN rail 35mm DIN rail