Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
  • Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
  • Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
  • Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
  • Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
  • Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
Find Similar Products
  • Overview
  • Product Description
  • Product Catalog
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
YCB8s-63PV
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Insert
Structure
DIN Rail
Poles Number
1,2,3,4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, 1,2,3,4
Certification
ISO9001-2000, CE, CB
Rated Current in(a)
1,2,3,4,6,10,16,20,25,32,40,50,63
Rated Operational Voltage(Ue)
DC400 DC800 DC1000 DC1200 DC1500
Number of Poles
1,2,3,4,
Installation Method
DIN35 Standard Rail
Breaking Capacity ICU
6ka/10ka
Protection Degree
IP20
Electrical Life (Times)
1500
Mechanical Life (Times)
20000
Standard
IEC60947-2
Transport Package
OEM/CNC
Specification
YCB8s-63PV
Trademark
CNC
Origin
China
Production Capacity
80000 Set/Sets Per Week

Product Description

Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

Product Description

Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB




General

YCB8s-63PV photovoltaic dedicated DC circuit breaker is mainly used in solar photovoltaic power generation systems.
The maximum working voltage can reach DC1500V, and the
rated current is up to 63A.
It is used for overload and short circuit protection of the line, and 
can quickly cut off the fault current of the DC distribution system, protecting the important components in the solar power generation system, ensuring the reliable operation of the solar photovoltaic power generation system.
standards:IEC60947-2


 
 
 
Product name
Shell frame Breaking capacity PV DC Number of poles Rated current Operating voltage
YCB8s -          63 H PV 2P 20A DC800V






YCB8s






63






Default:6KA H:10KA






PV





1P 2P 3P 4P

1A  2A  3A  4A  6A  10A 16A 20A 25A 32A 40A 50A 63A




DC400V  DC800V  DC1000V DC1200V DC1500V

Technical data



Appearance diagram
   
Number of poles 1P 2P 3P 4P
Rated working voltage Ue (V) DC400 DC800 DC1000 DC1200 DC1500
Rated insulation voltage Ui (V) DC400 DC1000 DC1200 DC1500
Rated impulse withstand voltage Uimp (KV) 4
Rated current In (A) 1,2,3,4,6,10,16,20,25,32,40,50,63
Ultimate short-circuit breaking capacity Icu (KA) Default: 6; H:10
Instantaneous tripping characteristics B,C,K
Service life (times) Mechanical 20000, electrical life 1500
Protection degree IP20
Operating ambient temperature -25°C~+40°C
Altitude ≤ 2000m
Wiring capacity (mm²) 25
Connection both upper and lower incoming lines are acceptable
Use Category A
Standard IEC60947-2
Product tripping characteristics
Rated current(A) Overload tripping characteristics Instantaneous tripping characteristics(A)
1.05In agreed non tripping time H (cold state) 1.30In agreed tripping time H (hot state)
In  63 1 1 B(4In±20%)  C(8In±20%)  K(10In±20%)
In > 63 2 2

Temperature correction factor table
Current correction value used in different environments
Rated current(A) Ambient temperature corresponding to rated current (A)
In(A) -25°C -20°C -10°C 0°C 10°C 20°C 30°C 35°C 40°C 50°C 60°C 75°C
6A 10.12 9.77 9.03 8.26 7.49 6.75 6 5.59 5.19 4.75 4.62 /
10A 17.41 16.75 15.41 14.04 12.71 11.35 10 9.09 8.21 7.9 8.7 7.86
16A 21.72 21.15 20.15 19.12 18.08 17.04 16 15.49 15.1 14.38 13.52 12.75
20A 25.86 25.79 24.61 23.47 22.32 21.16 20 19.43 18.83 18.58 17.1 16.3
25A 32.41 31.74 30.37 28.98 27.69 26.35 25 24.33 23.65 23.3 24.7 23.8
32A 44.83 43.62 41.29 38.96 36.67 34.33 32 30.83 29.67 30.7 30.8 30
40A 50.34 49.35 47.51 45.62 43.73 41.87 40 39.04 38.11 38.6 36.2 35.8
50A 63.79 62.48 59.99 57.48 54.98 52.5 50 48.76 47.48 47.1 47.5 46
63A 80 78.46 75.38 72.28 69.17 66.09 63 61.46 59.93 55.6 53.8 52.4
Accessories
The following accessories are suitable for YCB8s-63PV series, which can provide the functions of remote control of circuit breaker, automatic disconnection of fault circuit, status indication (breaking/closing/fault tripping).



a.   The total width of the accessories assembled is within 54mm, the order and quantity from left to right: OF, SD(3max) + MX, MX+OF+MCB, SD can only assemble up to 2 pieces ;
b.   Assembled with the body, no tools required;
c.   Before installation, check whether the technical parameters of the product meet the requirements of use, and operate the handle to open and close several times to check whether the mechanism is reliable.

Miniature circuit breaker accessories
•     Auxiliary contact OF
Remote indication of closing/opening status of circuit breaker.
•     Alarm contact SD
When the circuit breaker fault trips, it sends out a signal, together with a red indicator on the front of the device.
     Shunt release MX
When the power supply voltage is 70%~110%Ue, the remote control circuit breaker trips after receiving the signal.
•     Minimum making and breaking current: 5mA(DC24V)
•     Service life: 6000 times (operating frequency: 1s)
Technical data
Number of contacts 1NO+1NC 1NO+1NC /

Control voltage (VAC)
    110-415
48
12-24

Control voltage(V DC)
    110-415
48
12-24

Working current of contact
AC-12
Ue/Ie: AC415/3A
DC-12
Ue/Ie: DC125/2A

/

Shunt control voltage
    Ue/Ie:
AC:220-415/
0.5A
AC/DC:24-48/3
Width(mm) 9 9 18
Applicable Environmental Conditions and Installation
Storage temperature(°C) -40°C~+70°C
Storage humidity the relative humidity does not exceed 95% when at +25°C
Protection degree Level 2
Protection degree IP20
Installation environment Places without significant vibration and impact
Installation category Category II , Category III
Installation method TH35-7.5/DIN35 rail installation
Maximum wiring capacity 2.5mm²

Product Catalog

Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB
Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

Company Profile

 Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

Our Advantages

Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

 

Our Clients/Partners

Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

Packaging & Shipping

 

Factory Price Conventional Circuit Breaker 6ka IP20 Electrical Switch Overload Protection Solar MCB

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier