Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time

Product Details
Customization: Available
Task: Following
Structure: Closed-Loop
Still deciding? Get samples of US$ 80/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
  • Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
  • Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
  • Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
  • Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
  • Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Find Similar Products
  • Overview
  • Product Description
  • Product Catalog
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
YCQR7
Function
Automatic Control, Protection
Certification
RoHS, CCC, ISO: 9001, CE
Condition
Used
Customized
Non-Customized
Material
Aluminum Alloy
Scope of Application
3 Phase Rat Cage Asynchronous Motor
Power Bracket
5.5-450kw
Input Voltage
380V
Supply Frequency
50/60Hz
Cooling-Down Method
3 Road
Module Working Mode
Over a Long Period of Time
Human-Computer Interface
4 Line Cog Screen
Language
Chinese, English
Transport Package
Standard Packaging
Specification
YCQR7
Trademark
CNC
Origin
Zhejiang, China
HS Code
85362000
Production Capacity
8000units/Years

Product Description

Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time

Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Product Description

General
Read the ZR 900 installation instructions carefully before use. If you do not read the relevant instructions carefully, you will violate the relevant safety regulations, which may affect the normal use of the soft starter. To install the ZR900, please prepare the following tools : small word screwdriver, wire cutter, wrench, etc.

Operating conditions
Incoming line power supply: AC 380V ± 5% 50/60 HZ
Power supply is applicable: mouse cage three-phase asynchronous motor
Cooling mode: forced air cooling
App licable temperature: -10°C ~ ± 40°C ,1°C,2%, + 50°C
App licable humidity: 90% without frost
Place of use: No corrosive gas without conductive dust indoor is well ventilated
Elevation vibration: The altitude is below 3000 meters, and the vibration power device is below 0.5G
Technical data
 

project name performance index
scope of application 3 phase rat cage asynchronous motor
power bracket 5.5-450kW
input voltage 380V ± 15%
supply frequency 50/60HZ ± 5%
overload capacity 400%60sec,120% continuous
Adjustable current multiple From 1 to 5 times each time
Soft up time 1-90 Seconds
Module working mode over a long period of time
cooling-down method forced air cooling

Secondary interace terminal
on-off input 3 Road
relay output 1 (programmable) or 3 (programmable)
4-20MA Route (extension is optional)
RS485 1-way (extended as optional)
Protect Short circuit speed break, overcurrent, overheat protection, reverse time
overload, voltage phase deficiency, imbalance, lnsient stop, undervoltage,
overvoltage, underload, starting failure, phase sequence error.
Host overload protection Overload and reverse time limit, level 1 -5 is optional
Host current imbalance protection Unbalanced trip standard: 5- 100% any two-phase unbalanced trip delay: 1-60 seconds can be set
Host short circuit protection Quick break time . 0.18, can be set
Bus function Interface : RS485 protocol · ModbusRTU
human-computer interface 4 Line COG Screen
Language Chinese, English

Technical data
 

Order number Name Set the scope Windows default Explain
Soft-up parameters
A1 Start way 0~3 3 0: aging 1: voltage ramp
2: constant current3:current ramp
A2 Starting voltage 0~100% 45% 0,1,2 The starting mode is effective
A3 Initial current 0~2.5 Times 2.0 Times Method 3 valid
A4 Flow limit multiple 1.8~6.0 Times 3.5 Times Method 1,2,3 valid
A5 Sudden jump peak 0~100 90%  
A6 The jump cycle 0~2.0S 0.4S  
A7 Start delay 0~240.0S 0.0S Delayed start time
A8 Soft up time 0~90.0S 20.0S All starting modes are valid
A9 Soft stop time 0~60S 0S Set to 0 no soft stop function, non-0 valid
A10 Joint control delay 0~240.0S 0.0S Start the delay relay output, use with programmable relay

A11
mode of operation
0~6

3
0: Full open 1: keyboard 2: external control
3: keyboard + external control 4: Communication 5:Communication
+ keyboard
6:communication + external control
A12 Rated current 0~Current limit 100A Set according to the rated current on the motor nameplate
A13 Upper limitcurrent 0~200% 120% The relay is set to feed effectively
A14 Lower limit current 0~120% 90% The relay is set to feed effectively
A15 actuation time 0~10.0S 1.0S The relay is set to feed effectively
A16 Soft startplus time 0~60.0S 0 "Soft start time" does not complete the start, automatic extra time
A17 Soft strength 2.0 Times 0 "Soft start time" does not complete the start, automatic extra time
Protection parameters
A18 Short circuit multiple 0~12.0 Times 5.5 Times Set greater than (current limit multiple + soft starting force + 0.5), the whole process is effective
A19 Speed break time 0~2.00S 0.20S Short circuit block (break) time
A20 Overflow multiple 0~8.0 1.2 Bypass effective
A21 Overflow time 0~60.0S 10.0S If the overflow exceeds this value, block the silicon
A22 Overheat time 0~60.0S 10.0S When oyerheating exceeds this value, blocking the SCR,the whole process is effective
A23 Overload curve 1~6 1 Motor reverse time limit protection, reverse time limit curve
number, the larger the value, the longer the time, bypass (full
pressure) after the effective
A24 Lack of phase time 0~60.0S 10.0S If the voltage phase deficiency exceeds this value,the SCR is blocked, and the whole process is effective
A25 Current imbalance 0~100% 30% Current imbalance ratio, soft rise, bypass, soft stop effective
A26 Imbalance time 0~60.0S 5.0S If the accumulated time of imbalance exceeds this value, block the silicon controller
A27 Underpress ure lower limit 0~100% 70% Full effective
A28 Overpressure time 0~60.0S 2.0S If the accumulated time of underpressure exceeds this value, the thyristor is blocked
A29 Overpressure upper limit 0~150% 120% Full effective
A30 Overpressure time 0~60.0S 2.0S If the cumulative time of overpressure exceeds this value,the thyristors is blocked
A31 Under-load current 0~100% 50% Lower undercurrent, bypass and full pressure effective
A32 Adue time 0~30.0s 2.0s If the cumulative time exceeds this value, the thyristor is blocked
Protection switch
A33 Short-circuiting switch Close, open Open Output short-circuit protection is enabled or prohibited
A34 Overflow switch Close, open Open Overcurrent protection enables or forbids
A35 Overheat awitch Close, open Open Overheat protection enables or prohibited
A36 overload cut-out Close, open Open Motor overload protection is enabled or prohibited
A37 Lack of phases witch Close, open Open Input voltage phase absence protection enabled or prohibition
A38 Imbalance switch Close, open Open Current imbalance (output phase deficiency) protection enabled or prohibition
A39 Instantaneo us stop switch Close, open Open External instantaneous stop fault protection enabled or prohibited, enabling can be set to self-recovery
A40 Undervoltag e switch Close, open Open Input voltage protection enabled or prohibited
A41 Overvoltage switch Close, open Open Input voltage overvoltage protection enable or prohibited
A42 Starting failure Close, open Open Motor is not enabled or prohibited by full speed protection during
bypass (or full pressure)
A43 Underload switch Close, open Open Underload protection is enabled or prohibited
A44 Phase sequence switch Close, open Open Phase order error protection enables or prohibition
Communication parameters : not considered when not used
A45 principal and subordinate 0,1,2 0 0:Close 1:Host 2:slave
A46 Stop number 0~32 1  
A47 Digit capacity 0~12 8 Usually set to 8
A48 Stop bit 0~2 0 Usually set to 1
A49 Even-odd check 0~2 1 Usually set to 0
A50 Baud rate 0~96 8 Actual baud rate-baud rate*1200
A51 Current range 0~6000 1000 4 mA corresponds to 0 and 20 macorresponds to range values
Control
A52 Customer privilege     Password 10, go to the customer privilege menu
A53 Manufacturer setting     Password 111,enter the manufacturer setting menu

Specifications and models Overall dimensions(mm) Installation size(mm)
W1 H1 D W2 H2 D
18.5kW-37kW 105 240 170 85 214 M6
45kW-75kW 150 280 179 117 240 M6
90kW-115kW 200 370 214 168 328 M6
 
Product Catalog
Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Company Profile

Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time

Our Advantages

 

Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time
Our Clients/Partners

Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time

Packaging & Shipping

Closed-Loop 5.5-450kw Forced Air Cooling Starter Adjustable Soft Start Time

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier