0-600Hz Open-Loop Vector Control Torque Boost Functionality High Performance Frequency Converter
Product Details
| Customization: | Available |
|---|---|
| Application: | High Frequency Converter Transducer |
| Output Type: | Single |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Diamond Member Since 2006
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sign In to see all verified strength labels (23)
Find Similar Products
Basic Info.
- Model NO.
- YCB600
- Principle of Work
- Vector Control Transducer
- Switch Mode
- PAM Control
- Main Circuit Type
- Voltage
- Voltage of Power Supply
- Low Voltage Variable-Frequency Drive
- Link of Transformation
- AC-AC Variable-Frequency Drive
- Nature of DC Power
- Voltage Variable-Frequency Drive
- Function
- Constant Torque Universal Type
- Brand
- CNC
- Frequency Range
- 0-600Hz
- Carrier Frequency
- 2.0-20.0kHz
- Rated Power
- 0.4kw to 11kw
- Overload Capacity
- 180%
- Altitude
- 2000m
- Pollution Degree
- Level 2
- Input Voltage
- Single-Phase 200-240V, Three-Phase 360-440V
- Transport Package
- CNC/OEM
- Specification
- YCB600
- Trademark
- CNC/OEM
- Origin
- Zhejiang, China
- Production Capacity
- 8000units/Years
Product Description
General
An inverter is an electronic device used to control the speed of a motor. It achieves precise control of motor speed by changing the voltage and frequency that the motor receives.
Variable frequency drives are widely used in industrial applications for precise control of motor speeds, such as in fans, pumps, compressors, etc.
Operating condition
1. Ambient temperature: -10°C~+45°C
2. Relative humidity: ≤20% at 40°C; ≤90% at 20°C
3. Altitude: ≤2000m
4. Environmental conditions: no harmful gases and vapors, no conductive or explosive dust, no severe mechanical vibration
Type designation
Technical data
| Inverter Model (A: Economy Type) |
Input Voltage(V) | Rated OutputCurrent (A) | Adaptive motorPower (kw) |
| YCB600-2S0004G | 220-240 | 2.4 | 0.4 |
| YCB600-2S0007G | 220-240 | 4.5 | 0.75 |
| YCB600-2S0015G | 220-240 | 7.0 | 1.5 |
| YCB600-2S0022G | 220-240 | 10.0 | 2.2 |
| YCB600-2S0030G | 220-240 | 11.0 | 3.0 |
| YCB600-4T0007G | 360-440 | 2.1 | 0.75 |
| YCB600-4T0015G | 360-440 | 3.7 | 1.5 |
| YCB600-4T0022G | 360-440 | 5.0 | 2.2 |
| YCB600-4T0030G | 360-440 | 7.0 | 3.0 |
| YCB600-4T0040G | 360-440 | 9.0 | 4.0 |
| YCB600-4T0055G | 360-440 | 13.0 | 5.5 |
| YCB600-4T0075G | 360-440 | 17.0 | 7.5 |
| YCB600-4T0110G | 360-440 | 25.0 | 11.0 |
| Inverter Model (A: Economy Type) |
Input Voltage(V) | Rated OutputCurrent (A) | Adaptive motorPower (kw) |
| YCB600-2S0004G | 220-240 | 2.4 | 0.4 |
| YCB600-2S0007G | 220-240 | 4.5 | 0.75 |
| YCB600-2S0015G | 220-240 | 7.0 | 1.5 |
| YCB600-2S0022G | 220-240 | 10.0 | 2.2 |
| YCB600-2S0030G | 220-240 | 11.0 | 3.0 |
| YCB600-4T0007G | 360-440 | 2.1 | 0.75 |
| YCB600-4T0015G | 360-440 | 3.7 | 1.5 |
| YCB600-4T0022G | 360-440 | 5.0 | 2.2 |
| YCB600-4T0030G | 360-440 | 7.0 | 3.0 |
| YCB600-4T0040G | 360-440 | 9.0 | 4.0 |
| YCB600-4T0055G | 360-440 | 13.0 | 5.5 |
| YCB600-4T0075G | 360-440 | 17.0 | 7.5 |
| YCB600-4T0110G | 360-440 | 25.0 | 11.0 |
| Item | Item Description | |
Input |
Rated voltage & Frequency | Single-phase/3 Phase 200-240VAC,3 Phase 360-440VAC,50/60Hz |
| Allowable voltage working range | Voltage fluctuation range:±10% Voltage unbalance rate:<3%,Frequency fluctuation:≤5% | |
Ouput |
Rated voltage Frequency | 3 Phase 0~Input voltage VAC |
| 0.0~600Hz | ||
| Overload capacity | 110% long-term,150% 1 minute,180% 5seconds | |
Control your performance |
Control mode | V/F control,Simple vector control,Advanced vector control Torque contro |
| Frequency resolution | Digital setting:0.1Hz Analog setting:Maximum frequency×0.1% |
|
| Frequency accuracy | Digital setting:0.1Hz Analog setting:within 0.2%of the maximum output frequency |
|
| V/F Voltage frequency characteristic | Three modes:the first is a linear torque characteristic curve, the second is a square torque characteristiccurve,and the third is a user-set V/F curve. | |
Automatic limit current and limit voltage |
No matter in the process of acceleration,deceleration or stable operation,it will automatically detect the motor stator current and voltage,and suppress it within the allowable range according to the unique algorithm,minimizing the possibility of system fault tripping. | |
| Vector voltage-frequency characteristics | Automatically adjust output voltage-frequency ratio according to motor parameters and uniquealgorithm. | |
Torque characteristics |
Starting torque: 100% rated torque at 5.0Hz(VF control) 150% rated torque at 1.0Hz(vectorcontrol) |
|
| Current and suppression | Full current closed-loop control,completely avoid current impact,with perfect overcurrent and overvoltage suppression function | |
| Item | Item Description | |
Control your performance |
Under voltage suppression during operation | Especially for users with low grid voltage and frequent grid voltage fluctuations, even if the voltage is lower than the allowable range, the system can maintain the longest possible running time according to the unique algorithm and residual energy allocation strategy |
Slip compensation |
Setting range:0~100%,can automatically adjust the output frequency of the inverter according to the motor load, and reduce the rotation speed change of the motor caused by the load change |
|
| Carrier frequency | 2.0~20.0KHz | |
| Automatic voltage regulation operation |
Dynamic voltage stabilization, static voltage stabilization, and no voltage stabilization can be selected according to the need to obtain the most stable operation effect. | |
| Built-in PID | It can easily constitute a closed-loop control system, suitable for process control such as pressure control and flow control | |
Running |
Acceleration and deceleration time | 0.1~999.9s Continuous can be set |
| Running command | Operation panel control, external terminal control, serial communication control | |
Frequency setting |
Panel potentiometer setting, panel key setting, external control terminal increase/ decrease setting, analog voltage or current signal setting,terminal combination setting, serial communication setting, etc. |
|
| Output signal | One programmable relay output, one analog output | |
Brake |
Energy braking | Energy braking initial start voltage,return voltage andenergy braking rate are continuously adjustable |
| DC braking | Start and stop can be selected separately, action frequency 0.0~upper limit frequency, action current level 0~50%, action time 0~30s, continuous can be set | |
Other functions |
Frequency upper and lower limit, reverse running limit, jog function, counter, skip frequency operation, instantaneous power failure restart, fault automatic reset, etc. | |
| Protection function | Overcurrent,overload, overvoltage, undervoltage, overheating,short circuit, etc. | |
| LED Display | Can display the real-time of inverter running status, monitoring parameters,function parameters,fault codes and other information | |
| Optional Parts | Brake components, remote operation panel and connecting cable | |
| Structure | Cooling method | Forced air cooling |
| Installation method | Wall-mounted, rail-mounted | |
Control circuit terminal
| Category | Terminal label | Function Description | Electrical Specifications |
Analog power terminal |
10V |
External analog given power supply, and GND, AL terminals connected to potentiometers, frequency setting can be performed |
OUTPUT,10V/10mA DC voltage |
| Public end | GND | Signal common terminal | |
| Analog input terminal | AI | Analog voltage signalinput, reference ground isGND | INPUT, 0~10V DCvoltage |
Analog output terminal |
AO |
Programmable analog voltage output,the function is set by parameter F2.10,the reference ground is GND |
OUTPUT,0~10V DC voltage Or 0~20mA DC current |
Communi cation terminal |
485+ | Positive end of communication signal | |
| 485- | Communication signaln negative terminal |
| Category | Terminal label | Function Description | Electrical Specifications |
Multi-funct ion inputterminal |
X1 | It is valid when Xn(n=1,2.3.4)-GND is short-circuited,and its functions are respectively set by parameters F2.13~F2.16 |
INPUT, 0~5V levelsignal, Active low, 5mA |
| X2 | |||
| X3 | |||
| X4 | |||
Programmable outputterminals |
TA | Relay contact output,Normal: TA-TC disconnected;When in action: TA-TC is closed;The function is set byparameterF2.20 |
Contact Rating:NO: 240VAC-3A |
| TC |
| Inverter Model | Power(kg) | Dimension(MM) | |||||
| H | H1 | W | W1 | D | d | ||
| YCB600-2S0004G | 0.4 | 146 |
136.5 |
72 |
63 |
105 |
Φ4.5 |
| YCB600-2S0007G | 0.75 | ||||||
| YCB600-2S0015G | 1.5 | ||||||
| YCB600-2S0022G | 2.2 | ||||||
| YCB600-4T0007G | 0.75 | ||||||
| YCB600-4T0015G | 1.5 | ||||||
| YCB600-4T0022G | 2.2 | ||||||
| YCB600-4T0030G | 3.0 | ||||||
| YCB600-2S0030G | 3.0 | 182 |
172.5 |
87 |
78 |
127 |
Φ4.5 |
| YCB600-4T0040G | 4.0 | ||||||
| YCB600-4T0055G | 5.5 | ||||||
| YCB600-4T0040G | 4.0 | 240 |
229 |
118 |
106 |
155 |
Φ5.5 |
| YCB600-4T0055G | 5.5 | ||||||
| YCB600-4T0075G | 7.5 | ||||||
| YCB600-4T0110G | 11 | ||||||
| Dimensions of keypad base holes | Keypad thickness | ||||
| W | W1 | H | H1 | D | D1 |
| 53mm | 49.4mm | 79mm | 75.4mm | 15.9mm | 14.5mm |
• It needs to be equipped with an external display panel,WVhen the YCB600 series operation panel is led out.
• The opening size of the external display panel is:width 49.4mmx height 75.4mm.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Motor Control & Protection
- Variable Frequency Drive
- 0-600Hz Open-Loop Vector Control Torque Boost Functionality High Performance Frequency Converter
Related Categories
Hot Searches
More