Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor

Product Details
Customization: Available
Electricity Type: AC
Number of Pole: 3 or 4
Still deciding? Get samples of US$ 1/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor
  • Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor
  • Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor
  • Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor
  • Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
CJ19
Phase
3
Main Circuit Rating Voltage
500V
Main Circuit Rating Current
100A
Type
Ac Contactors
Rated Voltage
380V
Rated Current
25, 32, 43, 63A
Ambient Air Temperature
-5′c~+40′c
Altitude
2000m
Pollution Level
3
Frencurency
50Hz
Productivity
2, 000PCS/Day
Brand
CNC
Protective Characteristics
Sealed Relay
Load
High Power Relay
Size
Miniature
Usage
Lathe Relay, AC Contactor
Theory
AC Contactor
Action Principle
AC Contactor
Transport Package
Carton
Specification
25, 32, 43, 63A
Trademark
CNC, OEM
Origin
China
HS Code
85363000
Production Capacity
2, 000PCS/Day

Product Description

Factory overload protection AC 3 appliance surge protector Electrical Types of Contactor

Product Description


CJ19i contactor for capacitor switching (hereinafter called contactor) is suitable for the circuit of AC 50Hz/60Hz with rated rated voltage up to 690V. It is mainly used to add low voltage reactive power compensation equipment or cut off low voltage parallel capacitor. The contactor is equipped with a device to suppress the inrush current, which can effectively reduce the impact of the making inrush current on the capacitor and suppress the over-voltage when the capacitor is cut off.
Standard: IEC/EN 60947-4-1.


Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor
Contactor model CJ19i-25 CJ19s-25 CJ19i-32 CJ19s-32 CJ19i-43 CJ19s-43 CJ19i-63 CJ19s-63 CJ19i-80 CJ19s-80 CJ19i-95 CJ19s-95 CJ19i-115 CJ19s-115
Main circuit features  
Rated operational voltage(Ue) V 380/400
Rated isolation voltage(Ui) V 690
Rated current of controllable capacitor(In)
AC-6b 400V

A

17

29

36

43

58

72

87
Rated capacity of controllable AC-6b 230V kVar 6 9 10 15 22 22.5 35
AC-6b 400V kVar 12 18 20 30 40 45 60
capacitor(Qn)
Rated conventional heating current(Ith) A 25 32 43 63 80 95 115
Restrained surge capacity A ≤35In ≤55In
Mechanical durability 104 times 100
Electrical durability AC-6b 400V 104 times 15 12
Operating frequency cycles/h AC-6b 400V times/h 300 120
 
Coil features  
Controlled power voltage (Us) AC50Hz V 110, 220, 380

Operation voltage range
operation voltage V 85%~110%Us when install inclination angle is +22.5°; 70%~120%Us when install inclination angle is ±5°;
release voltage V 20%~75%Us when install inclination angle is +22.5°; 20%~65%Us when install inclination angle is ±5°;
Auxiliary contact features  
Number of auxiliary contact 12, 21
Rated conventional heating current(Ith) A 10
The minimum load can be connected to 6V×10mA
Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor

Company Profile

Factory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of ContactorFactory Overload Protection AC 3 Appliance Surge Protector Electrical Types of Contactor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now