Product Highlights

  • Multi-Function Protection: Provides overload, short-circuit, over/under-voltage, and phase loss protection for comprehensive circuit safety.
  • Smart LCD Display: Features LCD+LED indicators with RS-485 Modbus-RTU communication for real-time monitoring and data logging.
  • High Breaking Capacity: Offers up to 50kA short-circuit breaking capacity at AC400V, ensuring reliable performance in high-load scenarios.
  • Wide Current Range: Available in frame currents of 250A, 400A, 630A, and 800A with rated currents up to 800A for diverse applications.
  • Customizable Configuration: Supports 3 or 4 poles and customizable frame currents to meet specific installation and operational requirements.
  • Robust Durability: Designed for 1000 charged ON operations and up to 7000 OFF operations, ensuring long-term reliability.
  • Certified Safety: Complies with IEC60947-2 standards and holds VDE, CE, CB, and CCC certifications for global market access.
  • OEM/ODM Support: Manufacturer offers OEM and ODM services with 2 R&D engineers to support custom product development.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection pictures & photos
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection pictures & photos
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection pictures & photos
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection pictures & photos
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection pictures & photos
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection pictures & photos
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
    Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
    Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
    Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
    Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
    Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
  • Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
    Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection

Find Similar Products

Product Description

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
Product Description

General
The rated insulation voltage of YCM8YV series electronic liquid crystal molded case circuit breakeris 1000V. It is suitable for the distribution network with AC 50Hz, rated voltage of 400V and below and rated current up to 800A. Under normal circumstances, the  circuit  breaker  can  be  used  for  infrequent  switching  of circuits  and  infrequent starting of motors. It can protect the circuits from overload and short circuit, as well as
over-voltage, under-voltage and phase loss. Standards:IEC60947-2

Operating Conditions
1. The ambient temperature is -5ºC~+40ºC, and the altitude is no more than 2,000m.
2.Atmospheric conditions: the max. temperature is 40ºC, and the relative humidity of air is not more than 50%; higher relative humidity can be allowed at lower
temperature like 90% at 20ºC . Special measures shall betaken for occasional condensation due to temperature change.
3. The external magnetic field of the installation site shall not exceed 5 times of the
geomagnetic field in any direction, avoid large electromagneticinterference (such as  high-power motor or frequency converter) near the product, explosive and corrosive gas, as well as invasion by rain and snow, and keep the place dry and ventilated.
4. Class of pollution: Class 3; installation category: III.
Features
1. Environmental protection, Wide range of application
2. Easy to operate,Maintenance-free, High security
3. Clearly visible real isolation break
4. Single cabinet structure, field-configurable, and expandable as desired
5. Replace SF6 load switch ring main unit
Technical data

 

Type YCM8YV-250 YCM8YV-400 YCM8YV-630 YCM8YV-800
Frame Current(A) 250 400 630 800
Pole number 3,4 3,4 3,4 3,4
Rated Current (A)
100-250

160-400

252-630
252-630
320-800
Rated voltage (V) AC400V AC400V AC400V AC400V
Rated insulation voltage (V) AC1000V AC1000V AC1000V AC1000V
Short Circuit
Breaking Capacity (kA) Icu/Ics

AC400V

35/25

50/35

50/35

50/35

Operating    Circle Times
Charged ON 1000 1000 1000 1000
Not
charged
OFF
7000 4000 4000 4000
Dimension(mm) a-b-c-ca
3P

105-165-88-115

140-257-103-155

140-257-103-155

210-275-103-155
ca
 

4P

140-165-88-115

185-257-103-155

185-257-103-155

280-275-103-155

 

Spec. & Functions
Classification Description  
Display Mode LCD+LED indicator light  
Interface operation Key  
Protective functions
Current protection
Overload longtime delay protection  
Short-circuit short time delay protection  
Short-circuit instantaneous protection  
Overload pre-alarm function  

Voltage protection
Under-voltage and over-voltage protection functions  
Phase loss protection function  
Protection function of fault neutral line at power supply side ○
Protection function of voltage loss and trip at power supply side  

Communication function
DL/T 645-2007 Multi-functional meter communication protocol ○
Modbus-RTU communication protocol ○
Communication hardware 1-channel RS-485  

Function of external DI/O port
Auxiliary communication power input  
1-channel DI/O programmable control input  
1-channel passive contact output  




Fault record
Storage of 10 times of trip faults (the upper computer needs to read the feedback information uploaded each time for query of more records.)  
Record of max./min. voltage and current in 30 days  
Record of 10 self-check events of protector  
Record of 80 protection function enable/disable events  
Record of 10 gate position change events  
Record of 10 alarm events  
Record of 10 times of high voltage power loss and recovery  
Time function With the function of real-time clock which consists of YY, MM, DD, hh, mm and ss.  


Notes: symbol "  " indicates that this function is available; symbol " ○" indicates that this function can be selected; and symbol "-" indicates that this function is not available.

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection
 
Model
Size(mm)
YCM8YV-250 YCM8YV-400 YCM8YV-630 YCM8YV-800
Class 3 Class 4 Class 3 Class 4 Class 3 Class 4 Class 3 Class 4
L 165 257 275.5 275.5
W 105 140 140 184 210 280 210 280
A 35 43.5 70 70
B 144 230 243.5 243.5
C 24 31 45 45
D 21 29 30 30
E 22.5 31.5 24 26
F 116 155 155 155
a 126 194 243 243
b 35 44 70 70
Φd 4×Φ4.5 4×Φ7 4×Φ8 4×Φ8
Company Profile

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection

Our Advantages

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection

Our Clients/Partners

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection

Packaging & Shipping

Ycm8yv Series 3p/4p Molded Case Circuit Breaker for Overload and Short-Circuit Protection

 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI2531765". Items marked "verified" are certified.

Watch Video
Watch Video
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 146-148 Xinguang Avenue, Yueqing City, Wenzhou City, Zhejiang Province
verified Plant Area
24070 square meters
verified Number of Employees
275
verified Registered Capital
10,000,000 RMB
verified Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Ningbo Port

Our Production Capability & Technical Expertise

verified Main Products
Circuit Breaker, AC Contactor, Starters, Relays, Instruments, Switches, Fuses, Transformer, Switch Gear
verified Production Machines
Automatic Assembling \tFacility
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
2 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2018-05-08
Export Year
2004-01-01
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Number of Foreign Trading Staff
38
verified Overseas Agent/Branch
No

FAQ

What are the main protection functions?
The breaker provides overload, short-circuit, over-voltage, under-voltage, and phase loss protection, along with fault neutral line protection.
What communication protocols are supported?
It supports DL/T 645-2007 and Modbus-RTU protocols via a 1-channel RS-485 interface for integration with monitoring systems.
What is the rated insulation voltage?
The rated insulation voltage is AC 1000V, while the rated voltage is AC 400V.
Can the product be customized?
Yes, frame currents (250A-800A) and pole numbers (3 or 4) are customizable. OEM and ODM services are also available.
What certifications does the product have?
The product is certified with VDE, CE, CB, and CCC, and complies with the IEC60947-2 standard.
What is the short-circuit breaking capacity?
The breaking capacity ranges from 35/25 kA to 50/35 kA (Icu/Ics) depending on the specific model and frame current.
What data logging features are included?
It records 10 trip faults, max/min voltage/current over 30 days, self-check events, and protection enable/disable events.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now