GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer, General-Purpose High-Performance Current Vector
Output Type: Three Phase
Still deciding? Get samples of US$ 80/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
  • GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
  • GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
  • GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
  • GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
  • GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
Find Similar Products
  • Overview
  • Product Description
  • Product Catalog
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
YCB2000PV-T
Principle of Work
V/F Control Transducer
Switch Mode
PAM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type, Weaving, Papermaking, Wire Drawing, Machine Tool,
Brand
CNC
Input Voltage
380V
Phase Number
Three Phase
Rated Output Power
0.75kw-110kw
Input Frequency
50/60Hz
Pump Motor Voltage
3 Phase 380V
Voltage,at Mpp
500VDC~600VDC
Load Type
Constant Torque
Transport Package
CNC/OEM
Specification
YCB2000PV-T
Trademark
CNC/OEM
Origin
Zhejiang, China
HS Code
853690000
Production Capacity
50000/Year

Product Description

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

 

Product Description

 GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
Solar pumping system
The YCB2000PV solar pumping system serves to provide water in remote applicarions where electrical grid power is either unreliable or unavailable. The system pumps water using a high-voltage DC power source such as aphotovoltaic array of solar panels.
Since the sun is only available during certain hours of a day and only in good weather conditions, the water is generally
pumped into a storage pool or tank for furher usage. And water sources are those natural or special such as river, lake, well or waterway, etc.
Solar pumping system is constituted by solar module array, combiner box,liquid level switch, solar pump erc. It aims at
providing solutions for the region that suffers water shortage, no power supply or uncertain power supply.
 
General
In order to satisfy the demands of various pumping applications, YCB2000PV solar pump controller adopts Max Power Point Tracking and proven motor drive technology to maximize output from solar modules.
It supports both single phase
or three-phase AC input such as a generator or inverter from battery. The controller provides fault detection, motor soft start, and speed control. YCB2000PV controller is designed to proceed these features with the plug and play, ease of installation.

 
Selection
YCB2000PV    T 5D5 G
Model Output voltage Adaptive power Load type
Photovoltaic
Inverter
S: Single phase AC220V
T: Three phase AC380V
0D75:0.75KW
1D5:1.5KW
2D2:2.2KW
4D0:4.0KW
5D5:5.5KW
7D5:7.5KW
011:11KW
015:15KW
....
110:110KW
G: Constant torque
 
GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
Model YCB2000PV-S0D7G YCB2000PV-S1D5G YCB2000PV-S2D2G YCB2000PV-T2D2G YCB2000PV-T4D0G
Input data
PV Source
Max input voltage(Voc)[V]     400    750
Min input voltage, at mpp[V]   180  350
Recommended voltage,at mpp    280VDC~360VDC   500VDC~600VDC
Recommended amps input,at mpp[A]   4.7   7.3   10.4    6.2                             11.3
Recommended max power at mpp[kW]  1.5    3  4.4    11                              15
Alternate AC generator
Input voltage 220/230/240VAV(±15%),Single Phase 380VAV(±15%) Three Phase
Max amps(RMS)[A] 8.2 14.0 23 5.8 10.0
Power and va capability [kVA] 2.0 3.1 5.1 5.0 6.6
Output data
Rated output power[kW] 0.75 1.5 2.2 2.2 4
Rated output voltage 220/230/240VAC,Single Phase 380VAC,Three Phase
Max amps(RMS)[A] 4.5 7.0 10 5.0 9.0
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 1.0-1.2 2.0-2.4 3.0-3.5 3.0-3.5 5.2-6.4
Solar panel connection 250W×5P×30V 250W×10P×30V 250W×14P×30V 250W×20P×30V 250W×22P×30V
Applicable pump (kW) 0.37-0.55 0.75-1.1 1.5 1.5 2.2-3
Pump motor voltage(V) 3 phase 220 3 phase 220 3 phase 220 3 phase 380 3 phase 380
  
Model YCB2000PV-T5D5G YCB2000PV-T7D5G YCB2000PV-T011G YCB2000PV-T015G YCB2000PV-T018G
Input data
PV source
Max input voltage(Voc)[V]  750  
Min input voltage, at mpp[V]   350
Recommended voltage,at mpp 500VDC~600VDC
Recommended amps input,at mpp[A]   16.2   21.2   31.2      39.6   46.8
Recommended max power at mpp[kW]  22  30  22    30  37
Alternate AC generator
Input voltage 380VAV(±15%) ,Three Phase  
Max amps(RMS)[A]    15   20   26.0      35.0   46.0
Power and va capability [kVA]  9.0  13.0  17.0    23.0  25
Output data
Rated output power[kW] 5.5 7.5 11 15 18.5
Rated output voltage 380VAC,Three Phase
Max amps(RMS)[A] 13 17 25.0 32.0 37
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 7.2-8.8 9.8-12 14.3-17.6 19.5-24 24-29.6
Solar panel connection 250W×40P×30V
20 series 2 parallel
250W×48P×30V
24 series 2 parallel
250W×60P×30V
20 series 3 parallel
250W×84P×30V
21 series 4 parallel
250W×100P×30V
20 series 5 parallel
Applicable pump (kW) 3.7-4 4.5-5.5 7.5-9.2 11-13 15
Pump motor voltage(V) 3 phase 380 3 phase 380 3 phase 380 3 phase 380 3 phase 380

Model YCB2000PV-T022G YCB2000PV-T030G YCB2000PV-T037G YCB2000PV-T045G
Input data
PV source
Max input voltage(Voc)[V]   750
Min input voltage, at mpp[V] 350
Recommended voltage,at mpp 500VDC~600VDC
Recommended amps input,at mpp[A] 56.0 74.0 94.0   113
Recommended max power at mpp[kW] 44 60 74 90
Alternate AC generator
Input voltage   380VAV(±15%) ,Three Phase
Max amps(RMS)[A] 62.0 76.0 76.0   90.0
Power and va capability [kVA] 30.0 41.0 50.0 59.2
Output data
Rated output power[kW] 22 30 37 45
Rated output voltage 380VAC,Three Phase
Max amps(RMS)[A] 45 60 75 90
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 28.6-35.2 39-48 48.1-59.2 58.5-72
Solar panel connection 250W×120P×30V
20 series 6 parallel
250W×200P×30V
20 series 10 parallel
250W×240P×30V
22 series 12 parallel
250W×84P×30V
21 series 4 parallel
Applicable pump (kW) 18.5 22-26 30 37-40
Pump motor voltage(V) 3 phase 380 3 phase 380 3 phase 380 3 phase 380
 
Model YCB2000PV-T055G YCB2000PV-T075G YCB2000PV-T090G YCB2000PV-T110G
Input data
PV source
 
Max input voltage(Voc)[V] 750  
Min input voltage, at mpp[V]   350
Recommended voltage,at mpp 500VDC~600VDC
Recommended amps input,at mpp[A]   105 140   160   210
       
Recommended max power at mpp[kW]   55 75   90   110
Alternate AC generator
Input voltage   380VAV(±15%) ,Three Phase  
 
Max amps(RMS)[A]   113 157     180   214
 
Power and va capability [kVA]   85 114   134  
  160
Output data
Rated output power[kW] 55 75 93 110
Rated output voltage 380VAC,Three Phase
Max amps(RMS)[A] 112 150 176 210
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 53-57 73-80 87-95 98-115
Solar panel connection 400W*147P*30V
21series 7 parallel
400W*200P*30V
20 series 10 parallel
400W*240P*30V
20 series 12 parallel
400W*280P*30V
20 series 4 parallel
Applicable pump (kW) 55 75 90 110
Pump motor voltage(V) 3PH 380V

Model Size W(mm) H(mm) D(mm) A(mm) B(mm) Mounting
Aperture
YCB2000PV-S0D7G 125 185 163 115 175 4
YCB2000PV-S1D5G
YCB2000PV-S2D2G
YCB2000PV-T0D7G
YCB2000PV-T1D5G
YCB2000PV-T2D2G
YCB2000PV-T3D0G 150 246 179 136 230 4
YCB2000PV-T4D0G
YCB2000PV-T5D5G
YCB2000PV-T7D5G
YCB2000PV-T011G 218 320 218 201 306 5
YCB2000PV-T015G
YCB2000PV-T018G
YCB2000PV-T022G 235 420 210 150 404 5
YCB2000PV-T030G 270 460 220 195 433 6
YCB2000PV-T037G
YCB2000PV-T045G 320 565 275 240 537 6
YCB2000PV-T055G
YCB2000PV-T075G 380 670 272 274 640 8
YCB2000PV-T090G
YCB2000PV-T110G

Product Catalog

 

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive
GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive


  

Company Profile

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

Our Advantages

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

Our Clients/Partners

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

Packaging & Shipping

 

GPRS/Wi-Fi/Erhernet IEC Standard Pumps 2.2kw Water Inverter 1 Phase Solar VFD Pump Drive

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier