High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
  • High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
  • High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
  • High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
  • High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
  • High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
Find Similar Products
  • Overview
  • Our Services
  • Product Description
  • Product Catalog
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
YCB8s-63PVn
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Insert
Structure
MCB
Poles Number
1,2,3,4
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection
Certification
VDE, ISO9001-2000, CE, CB
Capacity
Default:6ka H:10ka
Number of Poles
1,2,3,4
Operating Voltage
DC 300 600 900 1200V
Rated Current
1-63A
Mechanical Life
20000
Electrical Life
1500
Protection Degree
IP20
Standard
IEC60947-2
Transport Package
CNC/OEM
Specification
YCB8s-63PVn
Trademark
CNC/OEM
Origin
Zhejiang, China
Production Capacity
80000units/Years

Product Description

Our Services

High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker

High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
Product Description

General
YCB8s-63PV photovoltaic dedicated DC circuit breaker is mainly used in solar photovoltaic power generation systems.
T
he maximum working voltage can reach DC1200V, and the 
rated current is up to 63A. 
It is used for overload and short circuit protection of the line, and can quickly cut off the fault current of the DC distribution system, protecting the important components in the solar power generation system - photovoltaic modules from the harm of  DC side reverse current and AC side feedback current caused by inverter faults, ensuring the reliable operation of the solar photovoltaic power generation system.

Standards:IEC60947-2

Features
The product can achieve non-polar wiring, ensuring reliable equipment safety.

Product name Shell frame Breaking capacity PV DC  Number of poles    Rated current     Operating voltage  
YCB8s - 63 H PVn 2P 20A DC600







YCB8s
 





63






Default:6KA H:10KA






PVn:Photovoltaic DC non-polarity





1P 2P 3P 4P

1A  2A  3A  4A  6A  10A 16A 20A 25A 32A 40A 50A 63A





DC300  DC600  DC900  DC1200
Technical data



Appearance diagram
   
Number of poles 1P 2P 3P 4P
Rated operating voltage Ue (V) DC300 DC600 DC900 DC1200
Rated insulation voltage Ui (V) DC300 DC600 DC900 DC1200
Rated impulse withstand voltage Uimp (KV) 6
Rated frame current (A) 63
Rated current In (A) 1,2,3,4,6,10,16,20,25,32,40,50,63
Ultimate short-circuit breaking capacity Icu (KA) Default: 6; H:10
Instantaneous tripping characteristic B,C,K
Service life (times) Mechanical 20000, electrical life 1500
Protection degree IP20
Environmental temperature for use -25°C~+40°C
Altitude ≤ 2000m
Wiring ability(mm²) 25
Connection both upper and lower incoming lines are acceptable
Use Category A
Standard IEC60947-2
Product tripping characteristics
Rated current(A) Overload tripping characteristics Instantaneous tripping characteristics(A)
1.05In agreed non tripping time H (cold state) 1.30In agreed tripping time H (hot state)
In  63 1 1 B(4In±20%)  C(8In±20%)  K(10In±20%)
In > 63 2 2
Temperature correction factor table
Current correction value used in different environments
Rated current(A) Ambient temperature corresponding to rated current (A)
In(A) -25°C -20°C -10°C 0°C 10°C 20°C 30°C 35°C 40°C 50°C 60°C 75°C
6A 10.12 9.77 9.03 8.26 7.49 6.75 6 5.59 5.19 4.75 4.62 /
10A 17.41 16.75 15.41 14.04 12.71 11.35 10 9.09 8.21 7.9 8.7 7.86
16A 21.72 21.15 20.15 19.12 18.08 17.04 16 15.49 15.1 14.38 13.52 12.75
20A 25.86 25.79 24.61 23.47 22.32 21.16 20 19.43 18.83 18.58 17.1 16.3
25A 32.41 31.74 30.37 28.98 27.69 26.35 25 24.33 23.65 23.3 24.7 23.8
32A 44.83 43.62 41.29 38.96 36.67 34.33 32 30.83 29.67 30.7 30.8 30
40A 50.34 49.35 47.51 45.62 43.73 41.87 40 39.04 38.11 38.6 36.2 35.8
50A 63.79 62.48 59.99 57.48 54.98 52.5 50 48.76 47.48 47.1 47.5 46
63A 80 78.46 75.38 72.28 69.17 66.09 63 61.46 59.93 55.6 53.8 52.4
Accessories
The following accessories are suitable for YCB8s-63PV series, which can provide the functions of remote control of circuit breaker, automatic disconnection of fault circuit, status indication (breaking/closing/fault tripping).
a.   The total width of the accessories assembled is within 54mm, the order and quantity from left to right: OF, SD(3max) + MX, MX+OF+MCB, SD can only assemble up to 2 pieces ;
b.   Assembled with the body, no tools required;
c.   Before installation, check whether the technical parameters of the product meet the requirements of use, and operate the handle to open and close several times to check whether the mechanism is reliable.

Miniature circuit breaker accessories
•     Auxiliary contact OF
Remote indication of closing/opening status of circuit breaker.
•     Alarm contact SD
When the circuit breaker fault trips, it sends out a signal, together with a red indicator on the front of the device.
     Shunt release MX
When the power supply voltage is 70%~110%Ue, the remote control circuit breaker trips after receiving the signal.
•     Minimum making and breaking current: 5mA(DC24V)
•     Service life: 6000 times (operating frequency: 1s)

Model
YCB8s-63 OF YCB8s-63 SD YCB8s-63 MX



Appearance
           



Types


1 2
14





94





2

C2          C1
 
Number of contacts 1NO+1NC 1NO+1NC /

Control voltage (VAC)
    110-415
48
12-24

Control voltage(V DC)
    110-415
48
12-24

Working current of contact
AC-12
Ue/Ie: AC415/3A
DC-12
Ue/Ie: DC125/2A

/

Shunt control voltage
    Ue/Ie:
AC:220-415/
0.5A
AC/DC:24-48/3
Width(mm) 9 9 18
Applicable Environmental Conditions and Installation
Storage temperature(°C) -40°C~+70°C
Storage humidity the relative humidity does not exceed 95% when at +25°C
Protection degree Level 2
Protection degree IP20
Installation environment Places without significant vibration and impact
Installation category Category II , Category III
Installation method TH35-7.5/DIN35 rail installation
Maximum wiring capacity 2.5mm²
 
Product Catalog
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
Company Profile
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
Our Advantages
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
Our Clients/Partners
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker
Packaging & Shipping
High Performance 1200V 6ka Efficient Modular Photovoltaic Advanced Compact 10ka DC Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier