The main function of the built-in bypass soft starter is to reduce the pressure on the motor during startup by controlling the voltage and current changes, thereby increasing startup ef- ficiency and extending the motor's lifespan.
The built-in bypass soft starter typically includes bypass contactors and control power supplies, enabling a smooth transition to bypass mode during startup to prevent the motor from experiencing excessive current and voltage shocks.
project name | performance index |
Adaptation power range | The built-in bypass soft starter of YCQR8 series is adapted for power ranging from 5.5 to 630 kW. |
Starting method |
Supports multiple starting methods, including current-limiting start and voltage ramp start. It is also capable of applying programmable jog start and start current limiting under each method. |
Protection functions |
Equipped with various protection functions, including overcurrent protection, input/output phase loss protection, thyristor short-circuit protection, overheat protection, leakage detection, electronic thermal overload protection, etc. |
Communication functions |
Some built-in bypass soft starters support MODBUS-RTU communication, allowing connection with up to 32 devices, and enabling automatic communication through setting baud rate and communication address. |
Adaptive power frequency | The built-in bypass soft starter features adaptive power frequency for 50/60Hz. |
Other parameters |
It has a 4-20mA current output function, suitable for various industrial environments, with strong anti-interference capabilities and easy adjustment methods |
K1A K1B K2A K2B K3A K3B DI STOP RUN COM + MA - +24V A+ B-
Fault closure reset cease start-up Public end Analog output 24V+ 485 communication |
|
||||||||||||||||||||||
Classification | Terminal markings | Terminal name | Function Description | ||||||||||||||||||||
Contact out put(assive) |
1,2 |
Start to the topNo delay inputOut (closed) |
The built-in bypass soft starter of YCQR8 series is adapted for power ranging from 5.5 to 630 kW. 1 FU |
||||||||||||||||||||
3,4 |
Initiate a mission Lingshi (closed) |
Supports multiple starting methods, including current-limiting start and voltage ramp start. It is also capable of applying programmable jog start and start current limiting under each method. |
|||||||||||||||||||||
5,6 |
Fault occurs Time(closed) |
Equipped with various protection functions, including overcurrent protection, input/output phase loss protection, thyristor short-circuit protection, overheat protection, leakage detection, electronic thermal overload protection, etc. |
|||||||||||||||||||||
Contact input(Active) |
7 |
Instantaneous stop input |
Some built-in bypass soft starters support MODBUS-RTU communication, allowing connection with up to 32 devices, and enabling automatic communication through setting baud rate and communication address. |
||||||||||||||||||||
8 | Soft stop input | The built-in bypass soft starter features adaptive power frequency for 50/60Hz. | |||||||||||||||||||||
9 |
Start Input |
Supports multiple starting methods, including current-limiting start and voltage ramp start. It is also capable of applying programmable jog start and start current limiting under each method. |
|||||||||||||||||||||
10 |
Public end |
Equipped with various protection functions, including overcurrent protection, input/output phase loss protection, thyristor short-circuit protection, overheat protection, leakage detection, electronic thermal overload protection, etc. |
|||||||||||||||||||||
Analog quantity output |
11,12 |
Analog output |
11,12 can measure the current signal that changes with the load, output 4-20mA, or 0-20mA optional,calibrationValue 100,calculation formula:D= . Where Ixis the actual16measured current value (mA),and D is the motorLoad current (%)(can also be understoodas the rated current corresponding to the soft start setting of 20mA) |
||||||||||||||||||||
DC voltage output | 13(24V+) 10(COM) | Can carry a 0.2A DC load, with 13 (24V+)as the positive pole of thepower supply and 10(COM)as the negative pole of the power supply | |||||||||||||||||||||
485 communi- cation | 14,15 | Please refer to 485 communication protocol for details |
Model number | W1 | H1 | D |
YCQR8-22KW-37KWAC220V | 150 | 285 | 195 |
YCQR8-45KW-55KWAC220V | 210 | 370 | 240 |
YCQR8-75KW-115KWAC220V | 260 | 540 | 255 |
YCQR8-132KW-160KWAC220V | 300 | 635 | 275 |
YCQR8-185KW-220KWAC220V | 400 | 730 | 295 |
YCQR8-22KW-75KWAC380V | 150 | 285 | 195 |
YCQR8-90KW-115KWAC380V | 210 | 370 | 240 |
YCQR8-132KW-220KWAC380V | 260 | 540 | 255 |
YCQR8-250KW-350KWAC380V | 300 | 635 | 275 |
YCQR8-400KW-500KWAC380V | 400 | 730 | 295 |