High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 40/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
  • High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
  • High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
  • High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
  • High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
  • High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
Find Similar Products
  • Overview
  • Product Catalog
  • Product Description
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
YCM8E
Arc-extinguishing Medium
Air
Installation
Insert
Structure
MCCB
Poles Number
3, 4
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection
Certification
ISO9001-2000, CE, CB
Adjustable Type
Electronic Adjustable
Rated Operating Current
16A to 800A
Pole Number
3p, 4p
Rated Operating Voltage
1000V
Max Inclination
22.5
Transport Package
Standard Packaging
Specification
YCM8E
Trademark
CNC/OEM
Origin
Zhejiang, China
HS Code
85362000
Production Capacity
80000units/Years

Product Description

High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
Product Catalog
High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker
 
Product Description

YCM8E Electronic Addjustable Circuit Breaker

General
YCM8E series electronic circuit breakers are applicable for low-voltage power systems of AC 50Hz, rated operating voltage up to 1000V and rated operating current from 16A to 800A.
Ambient and installation conditions
  Altitude up to 2000m;
  Ambient medium temperature should be within -5ºC to +40ºC (+45ºC for marine products);
  It can withstand the effect of damp air;
  It can withstand the effect of salt fog or oil mist;
  It can withstand the effect of moulds;
  It can withstand the effect of nuclear radiation;
  The max inclination is 22.5ºC .
  It still can work reliably when the ship subjects to normal vibration;
  It can still work reliably if the product subjects to the earthquake (4g).
  Places where the surrounding medium is free from explosion danger, and far away from gas or conductive dust that would erode the metal or destroy the insulation;
  Keep away from rain or snow.
Features
  Circuit breaker can be equipped with undervoltage release, shunt release, auxiliary contacts, alarm contacts, electric operating mechanism, rotary operating handle and other accessories.
  Circuit  breaker  has  protection  functions  of  overload   long   delay,  short-circuit  short  delay  and  short-circuit  instantaneous protection, the user can set the required protection characteristics (user only needs to operate the DIP switch for settings of protection function parameters).
  Circuit  breaker  has  ground  fault  and  thermal  analog  protection  functions,  pre-alarm  indication  over-current  indication,  load current indication, digital current analysis technology, and it can achieve a higher level of protection.
 

Panel and function description
Intelligent release panel
Selection Guide
Product Code Adjustable Type Code of frame size current Code of operating mode
YCM8
moulded case circuit breaker
E

E: electronic adjustable
160 P
nm=160  lnm=250 lnm=400 lnm=800 P: electric operation
Z : rotary handle
W: direct operation
 Electric operation DC1, DC2, DC3
 
Pole Number Code of Release Type and Internal Accessory Application
3
3: three poles
4: four poles

400
2: intelligent release
Accessory code, see accessory table
2
1: for distribution
2: for protecting the motor

Code of Four-pole Product
A
A: N-pole without protection, cannot close or open
B: N-pole without protection, can close and open
C: N-pole with protection, can close and open
D: N-pole with protection, cannot close or open


Main Technical Data
Frame Current(A) 160 250 400 630 800
Type
YCM8E-160H

YCM8E-250H

YCM8E-400H

YCM8E-630H
YCM8E-800H  YCM8E-1000H YCM8E-1250H
Pole number 3,4 3,4 3,4 3,4 3,4
 
 

 

 

 
 
Rated Current (A) 12-32, 25-63,
40-100,63-160

100-250

200-400

400-630
400-630, 500-800,
630-1000,
850-1250
Rated voltage (V) AC400V AC400V AC400V AC400V AC400V
Rated insulation voltage (V) AC1000V AC1000V AC1000V AC1000V AC1000V
Short Circuit
Breaking Capacity (kA) Icu/Ics

AC400V

35/25

35/25

50/35

50/35

50/35

Operating    Circle Times
Charged ON 1500 1000 1000 1000 1000
Not
charged
OFF
7000 7000 4000 4000 4000
Dimension(mm) a-b-c-ca
3P

90-155-88-115

105-165-88-115

140-257-103-155

140-257-103-155

210-257-103-155

ca

c

4P

120-155-88-115

140-165-88-115

185-257-103-155

185-257-103-155

280-257-103-155

Weight(kg)
3P 1.8 2.1 5.5 5.7 5.7
4P 2.3 2.6 7.0 7.5 7.5
Electric operating device (MD)          
External drive handle          
Automatic release Electronic type Electronic type Electronic type Electronic type Electronic type

Accessory table
Accessories of YCM8, YCM8LE, YCM8RT, YCM8E are the same.


Internal accessories
Internal accessories of YCM8, YCM8LE, YCM8RT, YCM8E series include undervoltage release, shunt release and auxiliary alarm release, their main technical parameters and wiring diagram are as follows:
 
Undervoltage release  
Rated voltage of power supply Main features



AC220, AC240 AC380, AC415
A. Undervoltage release should act when voltage drops to within 70% and 35% of the rated voltage.
B. The undervoltage release should not be able to close to prevent the circuit breaker from closing when voltage is lower than 35% of the rated voltage.
C. The undervoltage release should ensure to be closed and ensure reliable closing of the circuit breaker when voltage is equal to or greater than 85% of the rated voltage.
Shunt release  
Rated voltage of power supply Main features
DC24, DC110 AC220, AC380 Shunt release can work reliably when the rated voltage value is at 70% and 110%.
Auxiliary alarm contact  
Rated voltage of power supply Main features
Auxiliary switch
AC 125V 5A, AC 250V 3A
DC 125V0.4A, DC 125V0.2A

Shunt release can work reliably when the rated voltage value is at 70% and 110%.
Alarm switch
AC 125 5A, AC 250V 3A
DC 125V0.4A, DC 125V 0.2A

Provide differentiated signals for the circuit breaker at "normal work" and "fault free trip" positions.
Auxiliary alarm switch
AC 125V 5A, AC 250V 3A DC 125V0.4A.DC125V0.2A

Provide differentiated signals for the circuit breaker at "close", "open" and "fault free trip" positions.
 
Company Profile

High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker

Our Advantages

High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker

Our Clients/Partners

High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker

Packaging & Shipping

High Quality Low Voltage Breakers MCCB Precision Electrical Electronic Addjustable Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier