CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS

Product Details
Customization: Available
Warranty: 5 Year
Brand: CNC
Still deciding? Get samples of US$ 50/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
  • CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
  • CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
  • CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
  • CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
  • CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
Find Similar Products
  • Overview
  • Product Description
  • Product Catalog
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
Overview

Basic Info.

Model NO.
YCQ9HB
Operation
Electric
Certification
CCC, CE, ISO9001
Type
Dual Power Automatic Switch
Poles
2P
Output type
Dual
Current Specifications
16-63A
Number of Poles
2,3,4
Design Number
CB Class
Standards
IEC 60947-6-1.
Operating Frequency
50/60Hz
Circuit Breaker Disconnect Type
C-C Type; D-D Type
Rated Working Voltage Ue
AC 230V/50Hz
Rated Breaking Capacity
6ka
Protection Class
IP30
Rated Control Power
AC 230V/50Hz
Transport Package
CNC
Specification
YCQ9HB
Trademark
CNC
Origin
China
HS Code
8536200000
Production Capacity
10000/Day

Product Description

CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS

CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
 
Product Description

General
YCQ9HB ATS appliances are suitable for AC 50Hz, rated working voltage 400V and below, rated current 10A to 63A dual power supply system, the power supply system of the twopower sources: common power supply (N) and standby power supply (R) at the same time detection, when the power supply occurs undervoltage, phase failure power supply failure that is, automatic switching from the abnormal power supply to the normal power supply (can also be manually switched), to enhance the continuity and reliability of the power supply system in the use of the premises.

This
 improves the continuity, safety and reliability of the power supply system at the place of use.
Switching appliances are widely used in power systems, hospitals, postal and telecommuni- cation, firefighting, hotels, banks, airports, wharves, residential neighborhoods, TV stations,  facilities, shopping malls and other important places where the continuity of power    supply is required.

Standards: IEC 60947-6-1.




Operating conditions

1.   The ambient air temperature is -5 °C ~ +40 °C, and the average temperature within 24h does not exceed 35 °C.
2.   The altitude of the installation site does not exceed 2000m above sea level.
3.   The relative humidity of the air at the installation site should not exceed 50% at an ambient temperature of +40°C. Higher relative humidity   is possible at lower temperatures. For example, in the wettest month with an average minimum temperature of +20°C, the monthly average maximum relative humidity for that month can be up to 90%. Appropriate measures should be taken to prevent condensation due to tem-     perature changes
4.   The pollution level is 3. There is no danger of explosion in the surrounding air, and there are no gases or conductive dust that could corrode metals and destroy insulation.
5.   The installation category is III.
6.   The two power lines are connected to the upper end of the switching appliance and the load line is connected to the lower end, and must not be reversed.
7.   The installation site should be free from significant vibration and shock.

 


Technical data
Model Specification
Technical data
YCQ9HB-63
Rated working current le 10A, 16A, 20A, 25A, 32A, 40A, 63A
Rated working voltage Ue AC 230V/50Hz (2P), AC 400V/50Hz (3P, 4P)
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4kV
Rated short-circuit making capacity 9.18kA
Rated making and breaking capacity 6kA
Mechanical life 10,000 times
Electrical life 3000 times
Usage category AC-33iB
Electrical grade CB grade
Pole 2P, 3P, 4P
Delay time 0 ~ 30s adjustable
Electromagnetic compatibility environmen Environment B
Pollution degree 3
protection class IP30
Installation Vertical Fixed Installation
operating method Automatic / Manual
switch position Common position ( I ),Standby position ( II ), Disconnect position (0)
Rated control power AC 230V/50Hz
Power supply voltage Undervoltage switching: 165V±10%
Control Loss of voltage/phase out, undervoltage, overvoltage switching

 


Controller Functions
Control function
Auto/Manual Conversion Mode  
dichotomous  
Grid - Power Grid  
Grid -- generators  
self-referral  
abandon oneself and not return
serve as a backup
Monitor common power supplies and failover Phase failure/loss of voltage, undervoltage, overvoltage faults
Monitor backup power and failover Phase failure/loss of voltage, undervoltage, overvoltage faults
Fire control input (passive)  
Fire Feedback Output  
Adjustable delay time  
conversion delay 0s-30s adjustable
Return delay 0s-30s adjustable
Common and standby closing indication  
Common and standby power indication  
malfunction alarm  
overvoltage conversion  
Undervoltage conversion  
Loss of Pressure Conversion  
Out-of-phase conversion  
communication function  
Display Module light-emitting diode

Note: "  " means this function is available; "  " means this function is optional; " "means Customers require factory adjustments.

Product Structure Schematic

CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATSController Panel and Description
CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
Description of Controller Indicator Messages
Product status 1 2 3 4
Common power supply normal Ever Bright      
Common power closing   Ever Bright    
Backup power supply normal     Ever Bright  
Standby power closed       Ever Bright
Commonly used circuit breaker release Adorable Adorable    
Spare circuit breaker release     Adorable Adorable
Standby conversion delay       Adorable
Standby constant return delay   Adorable    
Product Conversion Failure Adorable   Adorable  
Fire switch   Adorable   Adorable
 

•    101#, 102# commonly used power supply external indication signal output (AC220V/0.5A active), 3P products commonly used zero line con- nected to the 101# terminal ;
•    103#, 104# common closing external indication signal output (AC220V/0.5A active) ;
•    201#, 202# standby power external indication signal output (AC220V/0.5A active), 3P products standby zero line connected to 201# terminal ;
   203#, 204# common closing external indication signal output (AC220V/0.5A active) ;
•    301#, 302#, 303# for generator start control signal passive output terminal, 301# for the public terminal, 302# for the normally closed terminal ; 303# for the normally open terminal, common power supply is normal when 303# and 301# closed, 302# and 301# disconnected ; common  power supply is abnormal when 302# and 301# closed, 303# and 301# disconnected ;
   401 #, 402 # for the fire linkage signal passive input, the port can only be connected to a set of external passive normally open contacts (if the fire signal is an active signal, must be transferred through a small relay relay normally open contacts into the port) when the external contact    closure controller immediately after control
   403# and 404# are passive output terminals for firefighting feedback signals. Under normal condition, the ports are normally open, and 403# and 404# are closed when there is a firefighting signal input to the controller to make the switch switch switch to the breaking position ;
•    501#, 502#, 503# are communication function consoles.
Product Catalog
CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS
Company Profile

CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS

Our Advantages

CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS

Our Clients/Partners

CB 16A 20A 32A 63A Automatic Switch Electric AC 220V 25A ATS

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier