General YCS8-series is applicable to photovoltaic power generation system. When surge overvoltage occurs in the system due to lightning stroke or other reasons The protector immediately conducts in nanosecond time to introduce the surge overvoltage to the earth, thus protecting the electrical equipment on the grid.
Features
T2/T1+T2 surge protection has two types of protection, which can can meet Class I
(10/350 μS waveform) and Class II (8/20 μS waveform) SPD test, and voltage
protection level Up ≤ 1.5kV;
Modular, large-capacity SPD, maximum discharge current Imax=40kA;
Pluggable module;
Based on zinc oxide technology, it has no power frequency aftercurrent and fast
response speed, up to 25ns;
The green window indicates normal, and the red indicates a defect, and the
module needs to be replaced;
Dual thermal disconnection device provides more reliable protection;
Remote signal contacts are optional;
Its surge protection range can be from power system to terminal equipment;
It is applicable to direct lightning protection and surge protection of DC systems
such as PV combiner box and PV distribution cabinet
|
S | 1+ | 40 | PV | 2P | DC600 | / |
Types | Test Category | Maximum discharge cu rrent |
Use category | Number of poles |
Maximum continuous working voltage |
Functions |
/:Standard type S: Upgraded type |
I+I:T1+T2 | 40:40KA | PV: Photovoltaic/ direct-current |
2:2P | DC600 | /:Non communication R: Remote communication |
3:3P | DC1000 | |||||
DC1500 (Type S only) |
||||||
II:T2 | 2:2P | DC600 | ||||
3:3P | Dc1000 | |||||
DC1500 (Type S only) |
Model | YCS8 | ||||
Standards | IEC61643-31:2018; EN 50539-11:2013+A1:2014 | ||||
Test category | T1+T2 | T2 | |||
Number of poles | 2P | 3P | 2P | 3P | |
Maximum continuous working voltage Ucpv | 600VDC | 1000VDC | 600VDC | 1000VDC | |
Maximum discharge current lmax(kA) | 40 | ||||
Nominal discharge current In(kA) | 20 | ||||
Maximum impulse current limp(kA) | 6.25 | / | |||
Voltage protection level Up(kV) | 2.2 | 3.6 | 2.2 | 3.6 | |
Response time tA(ns) | ≤25 | ||||
Remote and indication | |||||
Working status/fault indication | Green/red | ||||
Remote contacts | Optional | ||||
Remote terminal switching capability |
AC | 250V/0.5A | |||
DC | 250VDC/0.1A/125VDC 0.2A/75VDC/0.5A | ||||
Remote terminal connection capability | 1.5mm2 | ||||
Installation and environment | |||||
Working temperature range | -40ºC-+70ºC | ||||
Allowable working humidity | 5%.95% | ||||
Air pressure/altitude | 80k Pa.106k Pa/-500m..2000m | ||||
Terminal torque | 4.5Nm | ||||
Conductor cross section(maximum) | 35mm² | ||||
Installation method | DIN35 standard din-rail | ||||
Protection degree | IP20 | ||||
Shell material | Fire-proof level UL 94 V-0 | ||||
Thermal protection | Yes |