CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors

Product Details
Customization: Available
Electricity Type: AC
Number of Pole: 4
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
  • CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
  • CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
  • CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
  • CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
  • CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
CJX2
Phase
3
Main Circuit Rating Voltage
380/660/690V
Main Circuit Rating Current
100A
Type
Ac Contactors
Brand Name
CNC
Contactor Phase
3, 4
Electric Type
AC-3, AC-4
Contactor Type
AC Contractor
Place of Origin
Zhejiang, China (Mainland)
Transport Package
Export Packing
Specification
CE
Trademark
CNC Brand
Origin
China
Production Capacity
1000/Day

Product Description

CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors

Product Description


CJX2 series AC Contactor is suitable for using in the circuits of rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4.
CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric ContactorsCNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric ContactorsCNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
Specifications
Type     CJX2-09 CJX2-12 CJX2-18 CJX2-25 CJX2-32 CJX2-40 CJX2-50 CJX2-65 CJX2-80 CJX2-95
Rated insulation voltage (Ui)   V 690
Rated thermal current (Ith)   A 20 20 32 40 50 60 80 80 95 95
Rated operation current (Ie) AC-3, 380V A 9 12 18 25 32 40 50 65 80 95
AC-3, 660V A 6.6 8.9 12 18 21 34 39 42 49 55
AC-4, 380V A 3.5 5 7.7 8.5 12 18.5 24 28 37 41
AC-4, 660V A 1.5 2 3.8 4.4 7.5 9 12 14 17.3 21.3
Max. power of 3 phase motor controlled AC-3, 220V kW 2.2 3 4 5.5 7.5 11 15 18.5 22 25
AC-3, 380V kW 4 5.5 7.5 11 15 18.5 22 30 37 45
AC-3, 660V kW 5.5 7.5 10 15 18.5 30 33 37 45 55
Electrical life AC-3 10000 t 100 80 80 60
AC-4 10000 t 20 20 15 10
Mechanical life   10000 t 1000 800 800 600
Operation frequency AC-3 t/h 1200 600 600 600
AC-4 t/h 300 300 300 300
Matching fuse type     RT16-20 RT16-20 RT16-32 RT16-40 RT16-50 RT16-63 RT16-80 RT16-80 RT16-100 RT16-125
Matching thermal relay type     JR28-25 JR28-25 JR28-25 JR28-25 JR28-36 JR28-93 JR28-93 JR28-93 JR28-93 JR28-93
Wiring capacity   mm² 1.5 1.5 2.5 4 6 10 16 16 25 35
Coil      
Control power voltage (Us) AC V 36, 110, 127, 220, 380
Allowed control circuit voltage Close V 85%~110%Us
Open V 20%~75%Us(AC)
  Close VA 70 110 200
Keeping VA 8 11 20
Loss power W 1.8~2.7 3~4 6~10
Auxiliary contact      
Rated thermal current (Ith)   A 10
Rated operation voltage (Ue) AC-15 V 380
DC-13 V 220
Rated control capacity AC-15 VA 360
DC-13 W 33
Note:3 pole is normal type,not remarked in the type name.
CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric ContactorsCNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors
Specifications
Ambient temperature -5ºC~+40ºC
Altitude ≤2000m
Relative humidity The maximum temperature of 40 degrees, the air relative humidity not exceed 50%, at a lower temperature can allow for a higher relative humidity, if humidity changes as a result of occasional gel generated,should eliminate it.
Pollution level 3
Installation category III
Installation position The installation degree of the tilt and vertical plane should not exceed ±22.5°, should be installed in place with no significant impact shaking and vibration
Installation The installation of fastening screws can be used,the CJX1-9~38 contactor can also be installed on 35mm standard DIN rail.
CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric ContactorsCNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors

Company Profile

CNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric ContactorsCNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric ContactorsCNC Newest Designed Ycc1 (LCD1/CJX2) 380V AC Brands Electric Contactors


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now