Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

Zhejiang Changcheng Trading Co., Ltd.
  • Audited Supplier
  • 21 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive Protection: Provides overload, phase loss, and short circuit protection for three-phase motors.
  • High Current Capacity: Supports rated current up to 80A with insulation voltage up to 690V.
  • Certified Quality: Complies with ISO9001 and CCC standards for industrial reliability.
  • Long Mechanical Life: Designed for 10,000 mechanical operations ensuring durability.
  • Flexible Frequency: Operates effectively at both 50Hz and 60Hz rated frequencies.
  • Customizable Options: Offers competitive quotations and customizable rated frequency settings.

Product Images of Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter pictures & photos
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter pictures & photos
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter pictures & photos
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter pictures & photos
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter pictures & photos
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter pictures & photos
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
    Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
    Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
    Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
    Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
    Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
  • Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
    Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

Find Similar Products

Product Description

Our Services

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
 

Product Description

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

General

YCP5 series AC Motor Starter is suitable for circuits whose alternating voltage is up to 690V, current up to 80A. The product works to control the overload, phase loss, short  circuit  protection  and  infrequent  starts  of  a  three-phase  squirrel  cage asynchronous  motor.  The   Motor  Starter  can   protect  the  distributing   line  for infrequent load transfer, and it can also works as an isolator.

Operating conditions
1.  Installation altitude≤2000m
2.  Ambient air temperature -5ºC ~+40ºC average temperature of 24 hours must be below +35ºC
3.  Relative humidity below 90% when the temperature is +25ºC±5ºC
4.  Ambient pollution level: 3
5.  Installation category of the starter: III
Acting characteristic of each phase in distribution circuit breaker in the load balanced condition
No. Multiple of    setting current Acting time Initial state Ambient air temperature
1 1.0In ≤2h non-tripping Cold state +40ºC±2ºC
2 1.2In ≤2h tripping Start after 1 +40ºC±2ºC
Technical data
Rated insulation voltage Ui(V):690;
Rated work voltage Ue(V):230/240,400/415,440,550,690; Rated frequency Hz:5 0/60;
The grade rated current of shell lnm(A): 80; The rated voltage of disjointer ln(A);
The adjusting range of commuting current(A);
The cutting capacity for rated limit short circuit lcu(kA); The cutting capacity for rated work short circuit lcs(kA); The bearable voltage for rated shock Uimp(V): 6000;
Electrical life AC-3: 2000; Mechanical life: 10000.
Table 1
The adjusting
range of
commuting current
The cutting capacity for rated limit short circuit lcu,the cutting capacity for rated work short circuit lcs
230/240V 415V 500V 660V
Icu(kA) Ics, %Icu(kA) Icu(kA) Ics, %Icu(kA) Icu(kA) Ics, %Icu(kA) Icu(kA) Ics, %Icu(kA)
YCP5-25
0.1-0.16 100 100 100 100 100 100 -- --
0.16-0.25 100 100 100 100 100 100 -- --
0.25-0.4 100 100 100 100 100 100 -- --
0.4-0.63 100 100 100 100 100 100 -- --
0.63-1 100 100 100 100 100 100 -- --
1-1.6 100 100 100 100 100 100 -- --
1.6-2.5 100 100 100 100 100 100 3 75
2.5-4 100 100 100 100 100 100 3 75
4-6.3 100 100 100 100 50 100 3 75
6-10 100 100 100 100 10 100 3 75
9-14 100 100 15 50 6 75 3 75
13-18 100 100 15 50 6 75 3 75
17-23 50 50 15 50 4 75 3 75
20-25 50 50 15 50 4 75 3 75
24-32 50 50 10 50 4 75 3 75
YCP5-80
6-10 / / 100 50 8 100 4 100
10-16 / / 100 50 8 100 4 100
14-20 / / 100 50 8 100 4 100
16-25 / / 100 50 8 100 4 100
25-40 / / 35 50 8 75 4 75
40-63 / / 35 50 8 75 4 75
56-80 / / 15 50 4 100 2 100
Protection properties
Over-load Protection Properties
Series No. Multip le of   setting current Initial status Time Expected results Ambient
temperature
1 1.05 Cold status t≥2h Non-tripping +20°C±2°C
2 1.20 Heat status
(right after test.1)
t<2h Tripping +20°C±2°C
3 1.50 Heat status
(right after test.1)
Tripping class 10A t<2min
10   t<4min
Tripping +20°C±2°C
4 7.20 Cold status Tripping class 10A 2s<t≤10s 10   4s<t≤10s Tripping +20°C±2°C
Phase failure protection properties
Series No. Multiple of setting current Initial status Time Expected results Ambient
temperature
Any 2 phase The other phase
1 1.0 0.9   Cold status t≥2h Non-tripping +20°C±2°C
2 1.15 0   Heat status
(right after test.1)
t<2h Tripping +20°C±2°C


 


Type
Standard power ratings of 3-phase molors 50/60Hz in category AC-3
Current
setting range
220V 380V 415V 440V 500V 660V
kW kW kW kW kW kW
YCP5-25-ME01 - - - - - - 0.1-0.16
YCP5-25-ME02 - - - - - - 0.16-0.25
YCP5-25-ME03 - - - - - - 0.25-0.4
YCP5-25-ME04 - - - - - 0.37 0.4-0.63
YCP5-25-ME05 - - - 0.37 0.37 0.55 0.63-1
YCP5-25-ME06 - 0.37 - 0.55 0.75 1.1 1-1.6
YCP5-25-ME07 0.37 0.75 0.75 1.1 1.1 1.5 1.6-2.5
YCP5-25-ME08 0.75 1.5 1.5 1.5 2.2 3 2.5-4
YCP5-25-ME10 1.1 2.2 2.2 3 3.7 4 4-6.3
YCP5-25-ME14 2.2 4 4 4 5.5 7.5 6-10
YCP5-25-ME16 3 5.5 5.5 7.5 7.5 9 9-14
YCP5-25-ME20 4 7.5 9 9 9 11 13-18
YCP5-25-ME21 5.5 11 11 11 11 15 17-23
YCP5-25-ME22 5.5 11 11 11 15 18.5 20-25
YCP5-25-ME32 7.5 15 15 15 18.5 26 24-32
YCP5-80-ME10 1.1 2.2 2.2 3 3.7 4 6-10
YCP5-80-ME16 2.2 4 4 4 5.5 7.5 10-16
YCP5-80-ME20 4 7.5 7.5 7.5 10 11 14-20
YCP5-80-ME25 5.5 11 11 11 15 18.5 16-25
YCP5-80-ME40 11 18.5 22 22 25 33 25-40
YCP5-80-ME63 15 30 33 33 40 55 40-63
YCP5-80-ME80 22 40 45 45 55 63 56-80
Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter
 

Company Profile

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

Our Advantages

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

Our Clients/Partners

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter

Packaging & Shipping

Customized 80A Open Type Single Phase AC Electric Magnetic Price Motor Starter



 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI2531765". Items marked "verified" are certified.

Watch Video
Watch Video
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.
Zhejiang Changcheng Trading Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 146-148 Xinguang Avenue, Yueqing City, Wenzhou City, Zhejiang Province
verified Plant Area
24070 square meters
verified Number of Employees
275
verified Registered Capital
10,000,000 RMB
verified Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Ningbo Port

Our Production Capability & Technical Expertise

verified Main Products
Circuit Breaker, AC Contactor, Starters, Relays, Instruments, Switches, Fuses, Transformer, Switch Gear
verified Production Machines
Automatic Assembling \tFacility
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
2 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2018-05-08
Export Year
2004-01-01
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Number of Foreign Trading Staff
38
verified Overseas Agent/Branch
No

FAQ

What is the maximum rated current for this motor starter?
The shell rated current is up to 80A, suitable for circuits with current up to 80A.
What protection features does the YCP5 series offer?
It provides overload protection, phase loss protection, and short circuit protection for three-phase squirrel cage asynchronous motors.
Is this product certified?
Yes, the product holds ISO9001 and CCC certifications.
What is the mechanical life of the starter?
The mechanical life is rated for 10,000 operations.
Can the rated frequency be customized?
Yes, the rated frequency can be customized to 50Hz or 60Hz.
What is the maximum insulation voltage?
The rated insulation voltage (Ui) is 690V.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now