Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 40/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
338
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
  • Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
  • Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
  • Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
  • Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
  • Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Find Similar Products
  • Overview
  • Product Description
  • Product Catalog
  • Company Profile
  • Our Advantages
  • Our Clients/Partners
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
YCM8 HU
Arc-extinguishing Medium
Air
Installation
Insert
Structure
MCCB
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
CE, CB, CCC
Shell Frame Current
63A 160A 250A 400A 630A 800A
Product Type
AC High Voltage
Number of Poles
3 4
Certifications
CE
Isolation Function
Yes
Tripping Type
Thermal-Magnetic Type
Transport Package
Standard Packaging
Specification
YCM8 HU
Trademark
CNC
Origin
Zhejiang, China
HS Code
85362000
Production Capacity
8000units/Years

Product Description

Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Product Description

General
YCM8-HU series AC molded case circuit breaker is suitable for AC grid circuits with rated voltage up to AC1140V and rated current of 800A. The circuit breaker has the functions of overload long-time delay protection and short-circuit instantaneous protection, and  is  used to  distribute electric energy and  protect  lines  and  power supply equipment from overload, short circuit and other faults.

Features
 Ultra-wide breaking capacity:
rated  working  voltage  up  to  AC1140V  and  rated  current  up  to  800A.  Under AC800V   working   conditions,   Icu=Ics=36.5KA,   ensuring    reliable   short-circuit protection.
 Ultra-long arc-extinguishing chamber:
the  arc-extinguishing  chamber  has  been  improved  as  a  whole,  with  more  arc- extinguishing plates, greatly improving the product's breaking characteristics.
 Application of narrow-slot arc-extinguishing technology:
advanced current-limiting and narrow-slot arc-extinguishing technology is applied, which enables the high voltage and high short-circuit current to be cut off very quickly,  facilitating  the  extinguishing  of  the  arc  in  the  shortest  possible  time, effectively limiting the energy and current peak, and greatly reducing damage to cables and equipment caused by short-circuit currents


Selection

250 S HU / 3 125A AC800
Shell frame current Breaking capacity Product type / Number of poles Rated  current Rated  voltage
250(63~250)   320(250~320) 400(225~400) 630(500~630) 800(700~800)
S: Standard breaking
N: Higher breaking

HU:
AC high voltage


/


3
63, 80, 100, 125
140, 160, 180
200, 225, 250
280, 315, 320
350, 400, 500
630, 700, 800

AC800   AC1140
Technical data
Model YCM8- 250HU YCM8- 320HU YCM8- 400HU




Appearance
     
Shell frame current Inm(A) 250 320 400
Number of poles of products 3 3 3
AC working voltage(V) 415 690 800 1140 415 690 800 1140 415 690 800 1140
Rated insulation voltageUi(V) AC1150 AC1150 AC1150
Rated impulse withstand voltage Uimp(KV) 8 8 12

Rated current In(A)
63, 80, 100, 125,
140, 160, 180,
200, 225, 250

280, 315, 320
225, 250, 315,
350, 400

Ultimate short-circuit
breaking capacity Icu (kA)
S 85 50 36.5 10 85 50 36.5 10 85 50 36.5 10
N / / 100 60 50 15
Running short-circuit breaking capacity Ics(kA) Ics=100%Icu
Wiring method Up in and down out, down in and up out,    Down in and up out, up in and down out(3P)
Isolation function Yes
Tripping type Thermal-magnetic type
Electrical life(time) 3000 3000 2000 3000 3000 2000 1000 1000 700
Mechanical life(time) 20000 20000 10000
Standard IEC/EN60947-2
Attached accessories Shunt,Alarm,Auxiliary,Manual operation,Electric operation
Certifications CE
Overall
dimension (mm)
   
  W    
  Width(W) 107 107 182
Height(H) 180 180 250
Depth(D) 126 126 165
Technical data
Model YCM8-630HU YCM8-800HU




Appearance
   
Shell frame current Inm(A) 630 800
Number of poles of products 3 3
AC working voltage(V) 415 690 800 1140 415 690 800 1140
Rated insulation voltageUi(V) AC1150 AC1150
Rated impulse withstand voltage Uimp(KV) 12 12

Rated current In(A)

500, 630

630,700, 800

Ultimate short-circuit
breaking capacity Icu (kA)
S 85 50 36.5 10 85 50 36.5 10
N 100 60 50 15 100 60 50 15
Running short-circuit breaking capacity Ics(kA) Ics=100%Icu
Wiring method Up in and down out, down in and up out,    Down in and up out, up in and down out(3P)
Isolation function Yes
Tripping type Thermal-magnetic type
Electrical life(time) 1000 1000 1000 700 1000 1000 1000 700
Mechanical life(time) 5000 5000
Standard IEC/EN60947-2
Attached accessories Shunt,Alarm,Auxiliary,Manual operation,Electric operation
Certifications CE
Overall
dimension (mm)
    Width(W) 182 182
Height(H) 250 250
Depth(D) 165 165


Auxiliary contact
Auxiliary contact current parameters
Rated current of shell frame grade Agreed heating current Ith The rated working current at AC 400V
Inm<320 3A 0.30A
Inm>400 6A 0.40A
Shunt release
Generally installed in the Phase A of the circuit breaker,  when the rated control power voltage is between 70% - 110%, the shunt releaseshall make the circuit breaker trip reliably under all operating conditions.
Control voltage: conventional: AC 50Hz, 110V, 230V, 400V, DC 24V.
Note: when the power supply of the control circuit is DC24V, the following figure is recommended for the design of the shunt control circuit.
KA: DC24V intermediate relay, contact current capacity is 1A
K: the microswitch in series with the coil inside the release aid is a normally closed contact. When the circuit breaker is disconnected, the contact will automatically disconnect and close when it is closed.

Overall and mounting dimension of external accessories
Model and specification of rotating operating handle mechanism
Model H B B1 A A1 D
YCM8-250/320HU 188.5 116 126 90 35 4.2
YCM8-400/630/800HU 244 176 194 130 48 6.5
 

Model

L
A
B

C
E
Without zero arcing cover With zero   arcing cover Without zero arcing cover With zero   arcing cover
YCM8-250HU 40 100 165 40 40 100 165
YCM8-320HU 40 100 165 40 40 100 165
YCM8-400HU 40 100 165 40 40 100 165
YCM8-630HU 40 100 165 40 40 100 165
YCM8-800HU 40 100 165 40 40 100 165

 

Product Catalog
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Company Profile
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Our Advantages
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Our Clients/Partners
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker
Packaging & Shipping
Low Voltage Breakers Wide Breaking Capacity AC Molded Case Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier